Effect of thermal cycling on denture base and autopolymerizing reline resins

Objective This study evaluated the fracture toughness (FT) of denture base and autopolymerizing reline resins, with and without thermocycling (T). Material and Methods Specimens of each material (denture base acrylic resin - Lucitone 550 - L; autopolymerizing reline resins - Ufi Gel Hard-UH, Tokuyam...

Full description

Saved in:
Bibliographic Details
Main Authors: Cintia de Souza SILVA (Author), Ana Lucia MACHADO (Author), Carolina de Andrade Lima CHAVES (Author), Ana Claudia PAVARINA (Author), Carlos Eduardo VERGANI (Author)
Format: Book
Published: University of São Paulo, 2013-06-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_97f6e0b7bbd14d2bb97c68e8d0524bd2
042 |a dc 
100 1 0 |a Cintia de Souza SILVA  |e author 
700 1 0 |a Ana Lucia MACHADO  |e author 
700 1 0 |a Carolina de Andrade Lima CHAVES  |e author 
700 1 0 |a Ana Claudia PAVARINA  |e author 
700 1 0 |a Carlos Eduardo VERGANI  |e author 
245 0 0 |a Effect of thermal cycling on denture base and autopolymerizing reline resins 
260 |b University of São Paulo,   |c 2013-06-01T00:00:00Z. 
500 |a 1678-7765 
500 |a 10.1590/1679-775720130061 
520 |a Objective This study evaluated the fracture toughness (FT) of denture base and autopolymerizing reline resins, with and without thermocycling (T). Material and Methods Specimens of each material (denture base acrylic resin - Lucitone 550 - L; autopolymerizing reline resins - Ufi Gel Hard-UH, Tokuyama Rebase II-TR, New Truliner-NT and Kooliner-K), were produced, notched and divided into two groups (n=10): CG (control group of autopolymerizing reline resins and L): FT tests were performed after polymerization; TG (thermocycled group): FT tests were performed after T (5°C and 55°C for 5,000 cycles). Results: Results (MPa.m1/2) were analyzed by two-way ANOVA and Tukey's test (p=0.05). L exhibited the highest FT mean values in both groups (CG - 2.33; TG - 2.17). For the CG groups, NT showed the highest FT (1.64) among the autopolymerizing reline resins, and K the lowest (1.04). After T, when the autopolymerizing reline resins were compared, a statistically significant difference in FT was found only between the NT (1.46) and TR (1.00). Conclusions Thermocycling increased the FT of K and did not influence the FT of L, UH, TR and NT. 
546 |a EN 
690 |a Acrylic resins 
690 |a Denture bases 
690 |a Thermic treatment 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Journal of Applied Oral Science, Vol 21, Iss 3, Pp 219-224 (2013) 
787 0 |n http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572013000300219&lng=en&tlng=en 
787 0 |n https://doaj.org/toc/1678-7765 
856 4 1 |u https://doaj.org/article/97f6e0b7bbd14d2bb97c68e8d0524bd2  |z Connect to this object online.