Spectrophotometric evaluation of shade reproduction of pressable all-ceramic system on un-stained and stained tooth: An in vitro study

Purpose: To evaluate the shade reproduction of a pressable all-ceramic system placed on unstained and stained extracted maxillary central incisor using a color measurement spectrophotometer. In addition, to compare shade reproduction of this material with low translucency and medium opacity on unsta...

Cur síos iomlán

Sábháilte in:
Sonraí bibleagrafaíochta
Príomhchruthaitheoirí: Neelam Pande (Údar), Maithili S Kolarkar (Údar)
Formáid: LEABHAR
Foilsithe / Cruthaithe: Wolters Kluwer Medknow Publications, 2016-01-01T00:00:00Z.
Ábhair:
Rochtain ar líne:Connect to this object online.
Clibeanna: Cuir clib leis
Níl clibeanna ann, Bí ar an gcéad duine le clib a chur leis an taifead seo!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_98840d6757ae4583aa80a8e5ca8e7fa0
042 |a dc 
100 1 0 |a Neelam Pande  |e author 
700 1 0 |a Maithili S Kolarkar  |e author 
245 0 0 |a Spectrophotometric evaluation of shade reproduction of pressable all-ceramic system on un-stained and stained tooth: An in vitro study 
260 |b Wolters Kluwer Medknow Publications,   |c 2016-01-01T00:00:00Z. 
500 |a 0972-4052 
500 |a 1998-4057 
500 |a 10.4103/0972-4052.175711 
520 |a Purpose: To evaluate the shade reproduction of a pressable all-ceramic system placed on unstained and stained extracted maxillary central incisor using a color measurement spectrophotometer. In addition, to compare shade reproduction of this material with low translucency and medium opacity on unstained tooth and medium and high opacity on stained tooth. Materials and Methods: Total 45 discs, with difference in the opacity of core, were used. After spectrophotometric evaluation, shade reproduction of the discs was compared and calculated by formula: Δ E+ = ([Δ L+]2+ [Δ a+]2+ [Δ b+]2) 1/2. Results: Student's t-test showed that in a sample of 15, the values of Δ E+ for Group I - LT (Us.T.) lie between 0 and l, for Group II - MO (for Us. as well as S.T.) between l and 2, for Group III - HO (S.T.) are all above 5. Comparison among groups after t-test showed that mean Δ E+ values of Group I - LT is less than Group II - MO for the unstained tooth, Δ E+ for Group II - MO is less than average Δ E+ value of Group III - HO for stained tooth. Conclusion: All-ceramic with low translucency can be used for the fabrication of restoration on the unstained tooth as it gives the best shade reproduction. The medium opacity material may be used on the unstained as well as on stained tooth. However, the clinical implication of high opacity is limited when applied over the stained tooth as it is giving a shade reproduction, which is not within acceptable limits. 
546 |a EN 
690 |a Maxillary central incisor 
690 |a pressable all-ceramics 
690 |a shade reproduction 
690 |a spectrophotometer 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n The Journal of Indian Prosthodontic Society, Vol 16, Iss 1, Pp 63-69 (2016) 
787 0 |n http://www.j-ips.org/article.asp?issn=0972-4052;year=2016;volume=16;issue=1;spage=63;epage=69;aulast=Pande 
787 0 |n https://doaj.org/toc/0972-4052 
787 0 |n https://doaj.org/toc/1998-4057 
856 4 1 |u https://doaj.org/article/98840d6757ae4583aa80a8e5ca8e7fa0  |z Connect to this object online.