FACTORS INFLUENCING THE QUALITY OF DRINKING WATER FROM VENDING MACHINES IN THE INNER CITY OF BANGKOK
Objective: To investigate coliform contamination in drinking water from vending machines in the Rajvithi area of Bangkok. Study Design: Cross-sectional study Methods: Associated environmental factors were observed and self-administered questionnaires conducted. In total, 123 drinking-water samples w...
Saved in:
Main Authors: | , , |
---|---|
Format: | Book |
Published: |
YCAB Publisher,
2020-05-01T00:00:00Z.
|
Subjects: | |
Online Access: | Connect to this object online. |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
MARC
LEADER | 00000 am a22000003u 4500 | ||
---|---|---|---|
001 | doaj_99063aa0329f4db581e7e512b8d5bbaa | ||
042 | |a dc | ||
100 | 1 | 0 | |a Akemi Kita |e author |
700 | 1 | 0 | |a Tanasri Sihabut |e author |
700 | 1 | 0 | |a Kraichat Tantrakarnapa |e author |
245 | 0 | 0 | |a FACTORS INFLUENCING THE QUALITY OF DRINKING WATER FROM VENDING MACHINES IN THE INNER CITY OF BANGKOK |
260 | |b YCAB Publisher, |c 2020-05-01T00:00:00Z. | ||
500 | |a 2528-1542 | ||
500 | |a 2477-1570 | ||
500 | |a 10.36685/phi.v6i2.338 | ||
520 | |a Objective: To investigate coliform contamination in drinking water from vending machines in the Rajvithi area of Bangkok. Study Design: Cross-sectional study Methods: Associated environmental factors were observed and self-administered questionnaires conducted. In total, 123 drinking-water samples were collected to test coliform bacteria contamination. Results: Coliform bacteria were detected in 28.5% of samples. Links were found between coliform contamination and filter cleaning practices in 57 maintenance persons' responses. Filters cleaned < 3 times per year were at higher risk of coliform contamination (OR 14.49, 95% CI 1.76-125.00). A negative association was found between coliform contamination and vending-machine filters' being cleaned within 100 days (OR 0.21, 95% CI 0.05-0.83). Conclusion: A negative association was found between coliform contamination and vending-machine filters' being cleaned within 100 days (OR 0.21, 95% CI 0.05-0.83). These results emphasized the importance of effective vending-machine maintenance and monitoring drinking-water quality. | ||
546 | |a EN | ||
690 | |a drinking water | ||
690 | |a vending machine | ||
690 | |a bangkok | ||
690 | |a maintenance | ||
690 | |a Public aspects of medicine | ||
690 | |a RA1-1270 | ||
655 | 7 | |a article |2 local | |
786 | 0 | |n Public Health of Indonesia, Vol 6, Iss 2, Pp 47-56 (2020) | |
787 | 0 | |n https://stikbar.org/ycabpublisher/index.php/PHI/article/view/338 | |
787 | 0 | |n https://doaj.org/toc/2528-1542 | |
787 | 0 | |n https://doaj.org/toc/2477-1570 | |
856 | 4 | 1 | |u https://doaj.org/article/99063aa0329f4db581e7e512b8d5bbaa |z Connect to this object online. |