Effect of implantation Ti-6Al-4V ELI in femoral bone defect regeneration of Sprague Dawley rat

Ti-6Al-4V ELI is one of the most commonly used dental implant restore function. The solution treatment temperature variation can significantly increase the strength, but it is not yet known the effect of these temperature variations on the alloy's biocompatibility properties. Twelve female Spra...

Deskribapen osoa

Gorde:
Xehetasun bibliografikoak
Egile Nagusiak: I Nyoman Jujur (Egilea), Damisih (Egilea), Kartika Devy (Egilea), Shovy Suha (Egilea), Boy Muchlis Bachtiar (Egilea), Endang Winiati Bachtiar (Egilea)
Formatua: Liburua
Argitaratua: Wolters Kluwer Medknow Publications, 2020-01-01T00:00:00Z.
Gaiak:
Sarrera elektronikoa:Connect to this object online.
Etiketak: Etiketa erantsi
Etiketarik gabe, Izan zaitez lehena erregistro honi etiketa jartzen!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_9a5f9ef7ab0045368f056de5111036fd
042 |a dc 
100 1 0 |a I Nyoman Jujur  |e author 
700 1 0 |a Damisih  |e author 
700 1 0 |a Kartika Devy  |e author 
700 1 0 |a Shovy Suha  |e author 
700 1 0 |a Boy Muchlis Bachtiar  |e author 
700 1 0 |a Endang Winiati Bachtiar  |e author 
245 0 0 |a Effect of implantation Ti-6Al-4V ELI in femoral bone defect regeneration of Sprague Dawley rat 
260 |b Wolters Kluwer Medknow Publications,   |c 2020-01-01T00:00:00Z. 
500 |a 2231-4040 
500 |a 0976-2094 
500 |a 10.4103/japtr.JAPTR_74_20 
520 |a Ti-6Al-4V ELI is one of the most commonly used dental implant restore function. The solution treatment temperature variation can significantly increase the strength, but it is not yet known the effect of these temperature variations on the alloy's biocompatibility properties. Twelve female Sprague Dawley rats were divided into six groups as follows: the treated group, the control group, and the defect group without implant material. In the treated group, the femur bone defect was implanted with as-cast Ti-6Al-4V ELI, 850°C, 950°C, and 1050°C heat-treated Ti-6Al-4V ELI implant material. The rats were euthanized after 30 days postimplantation and evaluated histologically. The results show that the histological scoring of the specimen for femur defect without implant material is 2 (fibrous union and fibrocartilaginous), score with implant as-cast is 2.5, the sample with 850°C heat treatment material is 2.5, 950°C is 2.5, and the temperature at 1050°C is 2.5. The score of 2.5 is between score 2 and score 3: hemorrhage, fibrous union, fibrocartilaginous microhemorrhage, and mineralized cartilage union. In conclusion, there is no effect of different heat treatment temperatures for Ti-6Al-4V ELI implant material in rat bone regeneration's maturation level. 
546 |a EN 
690 |a bone regeneration 
690 |a heat treatment 
690 |a ti-6al-4v eli 
690 |a titanium implant 
690 |a Therapeutics. Pharmacology 
690 |a RM1-950 
690 |a Pharmacy and materia medica 
690 |a RS1-441 
655 7 |a article  |2 local 
786 0 |n Journal of Advanced Pharmaceutical Technology & Research, Vol 11, Iss 4, Pp 202-206 (2020) 
787 0 |n http://www.japtr.org/article.asp?issn=2231-4040;year=2020;volume=11;issue=4;spage=202;epage=206;aulast=Jujur 
787 0 |n https://doaj.org/toc/2231-4040 
787 0 |n https://doaj.org/toc/0976-2094 
856 4 1 |u https://doaj.org/article/9a5f9ef7ab0045368f056de5111036fd  |z Connect to this object online.