In vitro evaluation of the quality of obturation with capillary condensation technique and hybrid technique in teeth with simulated internal resorption cavity: A cone-beam computed tomography study

Aim: The quality of obturation with recent capillary condensation technique and hybrid technique in teeth with artificial internal resorption cavity needs to be evaluated. Methods: Calculation of sample size was done with G*Power software (version 3.1.9.4) (effect size d = 1.46). Eighteen single-can...

Повний опис

Збережено в:
Бібліографічні деталі
Автори: Girija S Sajjan (Автор), K Durga Prasad Naik (Автор), K Madhu Varma (Автор), Sai Lakshmi Durga Indukuri (Автор), Atchyut Kumar Gajja (Автор), B V Sindhuja (Автор)
Формат: Книга
Опубліковано: Wolters Kluwer Medknow Publications, 2023-01-01T00:00:00Z.
Предмети:
Онлайн доступ:Connect to this object online.
Теги: Додати тег
Немає тегів, Будьте першим, хто поставить тег для цього запису!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_9b3d63d5f8a34dc9ad452db2d9dd2a73
042 |a dc 
100 1 0 |a Girija S Sajjan  |e author 
700 1 0 |a K Durga Prasad Naik  |e author 
700 1 0 |a K Madhu Varma  |e author 
700 1 0 |a Sai Lakshmi Durga Indukuri  |e author 
700 1 0 |a Atchyut Kumar Gajja  |e author 
700 1 0 |a B V Sindhuja  |e author 
245 0 0 |a In vitro evaluation of the quality of obturation with capillary condensation technique and hybrid technique in teeth with simulated internal resorption cavity: A cone-beam computed tomography study 
260 |b Wolters Kluwer Medknow Publications,   |c 2023-01-01T00:00:00Z. 
500 |a 0970-7212 
500 |a 10.4103/endo.endo_79_22 
520 |a Aim: The quality of obturation with recent capillary condensation technique and hybrid technique in teeth with artificial internal resorption cavity needs to be evaluated. Methods: Calculation of sample size was done with G*Power software (version 3.1.9.4) (effect size d = 1.46). Eighteen single-canal mandibular premolars were decoronated at the cementoenamel junction for standardization of specimen length as 12 mm. Biomechanical preparation was done with ProTaper Universal rotary file up to F4. Internal resorption cavity was prepared with #08 size round bur 6 mm from the apex. Samples were distributed randomly into two groups. Group I: teeth with bioceramic sealer (EndoSequence BC Sealer, Brasseler, USA) application using conventional technique and hybrid technique of obturation. Group II: capillary condensation technique of bioceramic sealer (EndoSequence BC Sealer, Brasseler USA) using single-cone gutta-percha obturation. The voids in three segments of the root canal were measured with cone-beam computed tomography using "OnDemand3D App" software. Data were statistically analyzed by one-way analysis of variance (ANOVA) and multiple comparisons of Tukey honestly significant difference tests with P < 0.05. Results: The mean area of the void was 0.3963 ± 0.3299 mm2 for Group I and 0.4022 ± 0.4101 mm2 for Group II. There was a difference in the number of voids present in different sections of the root within a group with significance but not between the groups. Conclusion: Capillary condensation technique with single-cone obturation is comparable to conventional sealer application and hybrid technique of obturation for filling internal resorption cavity. 
546 |a EN 
690 |a bioceramic sealer 
690 |a cone-beam computed tomography 
690 |a endosequence bc sealer 
690 |a internal resorption 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Endodontology, Vol 35, Iss 1, Pp 24-29 (2023) 
787 0 |n http://www.endodontologyonweb.org/article.asp?issn=0970-7212;year=2023;volume=35;issue=1;spage=24;epage=29;aulast=Sajjan 
787 0 |n https://doaj.org/toc/0970-7212 
856 4 1 |u https://doaj.org/article/9b3d63d5f8a34dc9ad452db2d9dd2a73  |z Connect to this object online.