The Perfect Circle Technique Shows Poor Inter-rater Reliability in Measuring Anterior Glenoid Bone Loss on Magnetic Resonance Imaging

Purpose: To evaluate the reliability of the perfect circle methodology for measurement of glenoid bone loss in patients with anterior glenohumeral instability. Methods: We performed a chart review of retrospectively collected patients who underwent isolated arthroscopic anterior labral repair betwee...

Full description

Saved in:
Bibliographic Details
Main Authors: Nata Parnes, M.D (Author), Clare K. Green, B.S (Author), Emily I. Wynkoop, M.D (Author), Adam Goldman, D.O (Author), Keith Fishbeck, D.O (Author), Kyle J. Klahs, D.O (Author), Robert H. Rolf, M.D (Author), John P. Scanaliato, M.D (Author)
Format: Book
Published: Elsevier, 2024-04-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_9cce9f2a7d514b6fbda29b6c45af43ab
042 |a dc 
100 1 0 |a Nata Parnes, M.D.  |e author 
700 1 0 |a Clare K. Green, B.S.  |e author 
700 1 0 |a Emily I. Wynkoop, M.D.  |e author 
700 1 0 |a Adam Goldman, D.O.  |e author 
700 1 0 |a Keith Fishbeck, D.O.  |e author 
700 1 0 |a Kyle J. Klahs, D.O.  |e author 
700 1 0 |a Robert H. Rolf, M.D.  |e author 
700 1 0 |a John P. Scanaliato, M.D.  |e author 
245 0 0 |a The Perfect Circle Technique Shows Poor Inter-rater Reliability in Measuring Anterior Glenoid Bone Loss on Magnetic Resonance Imaging 
260 |b Elsevier,   |c 2024-04-01T00:00:00Z. 
500 |a 2666-061X 
500 |a 10.1016/j.asmr.2024.100905 
520 |a Purpose: To evaluate the reliability of the perfect circle methodology for measurement of glenoid bone loss in patients with anterior glenohumeral instability. Methods: We performed a chart review of retrospectively collected patients who underwent isolated arthroscopic anterior labral repair between January 1 and June 30, 2021, using our institution's electronic medical records. The inclusion criteria included isolated anterior shoulder instability with anterior labral repair and corroborated tears on magnetic resonance imaging. A total of 9 raters, either sports or shoulder and elbow fellowship-trained orthopaedic surgeons, each evaluated the affected shoulder magnetic resonance imaging scans twice, with a minimum of 2 weeks between measurements. Measurements followed the "perfect circle" technique and included projected anterior-to-posterior glenoid diameter, amount of posterior bone loss, and percentage of posterior bone loss. Intrarater reliability and inter-rater reliability were then determined by calculating intraclass correlation coefficients (ICCs). Results: Ten consecutive patients meeting the selection criteria were chosen for inclusion in this analysis. Average estimated bone loss for the cohort was 2.45 mm, and the mean estimated glenoid diameter of the involved shoulder was 28.82 mm. The average percentage of bone loss measured 8.54%. The ICC for interobserver reliability was 0.55 for the perfect circle diameter and 0.17 for the anterior bone loss measurement (poorly to moderately reliable). The ICC for intraobserver reliability was 0.69 for the perfect circle diameter and 0.71 for anterior bone loss (moderately reliable). Conclusions: The perfect circle technique for estimating anterior glenoid bone loss on magnetic resonance imaging was found to have moderate intrarater reliability; however, reliability between observers was found to be moderate to poor. Level of Evidence: Level IV, diagnostic case series. 
546 |a EN 
690 |a Sports medicine 
690 |a RC1200-1245 
655 7 |a article  |2 local 
786 0 |n Arthroscopy, Sports Medicine, and Rehabilitation, Vol 6, Iss 2, Pp 100905- (2024) 
787 0 |n http://www.sciencedirect.com/science/article/pii/S2666061X24000233 
787 0 |n https://doaj.org/toc/2666-061X 
856 4 1 |u https://doaj.org/article/9cce9f2a7d514b6fbda29b6c45af43ab  |z Connect to this object online.