Aim: The aim of this study was to measure the amount of material extruded in the periapical area using three irrigation needles (Max-I-Probe, NaviTip Fx and IrriFlex flexible needle). Materials and Methods: Mandibular premolars were selected for this study and glass vials were used to gather the ext...

Full description

Saved in:
Bibliographic Details
Main Author: Maha A Habeeb (Author)
Format: Book
Published: Wolters Kluwer Medknow Publications, 2023-01-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_9ceb142783d541a9969b5365bb55e051
042 |a dc 
100 1 0 |a Maha A Habeeb  |e author 
245 0 0 |a Comparative evaluation of debris and irrigation extruded apically using different design of needles and penetration depth - An In Vitro study 
260 |b Wolters Kluwer Medknow Publications,   |c 2023-01-01T00:00:00Z. 
500 |a 0970-9290 
500 |a 1998-3603 
500 |a 10.4103/ijdr.ijdr_32_23 
520 |a Aim: The aim of this study was to measure the amount of material extruded in the periapical area using three irrigation needles (Max-I-Probe, NaviTip Fx and IrriFlex flexible needle). Materials and Methods: Mandibular premolars were selected for this study and glass vials were used to gather the extruded debris and they were preweighed. The samples were divided into two groups: Group A (1 mm penetration of needle from working length), which was subdivided into three subgroups: Subgroup A1: Irrigation was made by Max-I-Probe. Subgroup A2: Irrigation was made by NaviTip Fx. Subgroup A3: Irrigation was made by IrriFlex flexible needle. Group B (3 mm penetration of needle), which was subdivided into three subgroups: Subgroup B1: Irrigation was made by Max-I-Probe. Subgroup B2: Irrigation was made by NaviTip Fx. Subgroup B3: Irrigation was made by IrriFlex flexible needle. XP-endo Shaper was used for chemomechanical preparation. After removal from vials, the teeth were incubated and then removed from the incubator and weighed again three times. The average of the readings was taken. Analysis of variance (ANOVA) and least significance difference tests were applied to analyse data. Results: All of the needles caused debris extrusion. There was a significant difference between groups (P ≤ 0.001) according to the depth of penetration. The lowest value for debris was observed in subgroup B3 while subgroup A2 had shown the highest mean. Conclusion: Results revealed that the design and depth of needles significantly affected the debris extrusion. Using more flexible needles and shorter penetration depth for irrigation so that we don't need to push the needles so far apically. 
546 |a EN 
690 |a debris 
690 |a evaluation 
690 |a needles 
690 |a penetration depth 
690 |a therapeutic irrigation 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Indian Journal of Dental Research, Vol 34, Iss 3, Pp 266-269 (2023) 
787 0 |n http://www.ijdr.in/article.asp?issn=0970-9290;year=2023;volume=34;issue=3;spage=266;epage=269;aulast=Habeeb 
787 0 |n https://doaj.org/toc/0970-9290 
787 0 |n https://doaj.org/toc/1998-3603 
856 4 1 |u https://doaj.org/article/9ceb142783d541a9969b5365bb55e051  |z Connect to this object online.