Assessment of titanium level in submucosal plaque around healthy implants and implants with peri-implantitis: A clinical study
Background: The present study focused on assessing the level of titanium in submucosal plaque in the peri-implant area with peri-implantitis in comparison to healthy implants. Methodology: Sixty patients with titanium dental implants were recruited. The degree of titanium in submucosal plaque around...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Book |
Published: |
Wolters Kluwer Medknow Publications,
2021-01-01T00:00:00Z.
|
Subjects: | |
Online Access: | Connect to this object online. |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
MARC
LEADER | 00000 am a22000003u 4500 | ||
---|---|---|---|
001 | doaj_a0b6fe9f1f0a40da8a2d78865582d52d | ||
042 | |a dc | ||
100 | 1 | 0 | |a Juzer Rasul |e author |
700 | 1 | 0 | |a Manoj Kumar Thakur |e author |
700 | 1 | 0 | |a Barkha Maheshwari |e author |
700 | 1 | 0 | |a Nausheen Aga |e author |
700 | 1 | 0 | |a Harsh Kumar |e author |
700 | 1 | 0 | |a Monica Mahajani |e author |
245 | 0 | 0 | |a Assessment of titanium level in submucosal plaque around healthy implants and implants with peri-implantitis: A clinical study |
260 | |b Wolters Kluwer Medknow Publications, |c 2021-01-01T00:00:00Z. | ||
500 | |a 0975-7406 | ||
500 | |a 10.4103/jpbs.JPBS_815_20 | ||
520 | |a Background: The present study focused on assessing the level of titanium in submucosal plaque in the peri-implant area with peri-implantitis in comparison to healthy implants. Methodology: Sixty patients with titanium dental implants were recruited. The degree of titanium in submucosal plaque around peri-implantitis and healthy implants was estimated using inductively coupled plasma mass spectrometry. Results: The mean ± standard deviation probing depth in Group I was 3.12 ± 1.1 and in Group II was 7.2 ± 2.5; gingival index was 0.64 ± 0.3 and 1.64 ± 0.8 in Group I and Group II, respectively. The plaque index was 0.82 ± 0.2 in Group I and 1.5 ± 0.6 in Group II. The mean plaque mass in Group I was 24.1 ± 3.8 ng/ul and 49.3 ± 6.4 ng/ul in Group II. The mean titanium level in Group I was 0.08 ± 0.02 μg and in Group II was 0.91 ± 0.04 μg. A highly significant difference between both groups was found (P < 0.05). Conclusion: There was a significantly higher titanium level in submucosal plaque around dental implants with signs of peri-implantitis as compared to healthy dental implants. | ||
546 | |a EN | ||
690 | |a dental implants | ||
690 | |a peri-implantitis | ||
690 | |a submucosal plaque | ||
690 | |a Pharmacy and materia medica | ||
690 | |a RS1-441 | ||
690 | |a Analytical chemistry | ||
690 | |a QD71-142 | ||
655 | 7 | |a article |2 local | |
786 | 0 | |n Journal of Pharmacy and Bioallied Sciences, Vol 13, Iss 5, Pp 383-386 (2021) | |
787 | 0 | |n http://www.jpbsonline.org/article.asp?issn=0975-7406;year=2021;volume=13;issue=5;spage=383;epage=386;aulast=Rasul | |
787 | 0 | |n https://doaj.org/toc/0975-7406 | |
856 | 4 | 1 | |u https://doaj.org/article/a0b6fe9f1f0a40da8a2d78865582d52d |z Connect to this object online. |