Histological In Vivo Evaluation of Intense Pulsed Light Technology: Assessing the Safety on Oral Soft and Hard Tissues

Intense pulsed light (IPL) is used for aesthetic and therapeutic purposes. According to recent literature, utilizing IPL may boost upregulation of anti-inflammatory cytokines, and downregulation of pro-inflammatory cytokines. Concerns have been raised about potential thermal damage to the soft and h...

Full description

Saved in:
Bibliographic Details
Main Authors: Yaniv Mayer (Author), Amit Shenhav (Author), Amin Younis (Author), Eran Gabay (Author), Hadar Giladi Zigdon (Author)
Format: Book
Published: MDPI AG, 2024-05-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_a0c5023ed43a4c9ab2c25f31f6eff4d3
042 |a dc 
100 1 0 |a Yaniv Mayer  |e author 
700 1 0 |a Amit Shenhav  |e author 
700 1 0 |a Amin Younis  |e author 
700 1 0 |a Eran Gabay  |e author 
700 1 0 |a Hadar Giladi Zigdon  |e author 
245 0 0 |a Histological In Vivo Evaluation of Intense Pulsed Light Technology: Assessing the Safety on Oral Soft and Hard Tissues 
260 |b MDPI AG,   |c 2024-05-01T00:00:00Z. 
500 |a 10.3390/dj12060151 
500 |a 2304-6767 
520 |a Intense pulsed light (IPL) is used for aesthetic and therapeutic purposes. According to recent literature, utilizing IPL may boost upregulation of anti-inflammatory cytokines, and downregulation of pro-inflammatory cytokines. Concerns have been raised about potential thermal damage to the soft and hard tissues in the oral cavity. Therefore, the aim of this study was to determine the safety of using IPL of various intensities in the tissues of the oral cavity. Methods: Three adult pigs were included in the trial. The oral cavity was divided into four quadrants and projected with a wide range of IPL settings. Alveolar bone, buccal mucosa, and gingival tissue samples were taken immediately and after 24 h. In each animal, one quadrant of the jaw was left untreated and served as a control. All samples were processed and stained with H&E. Results: Clinical examination showed no evidence of changes in the integrity of the examined tissues. Histological examination of the different tissues did not demonstrate significant thermal damage or changes in the characterization of the cells compared to the control tissues. Conclusions: The use of IPL in the oral cavity is safe and does not negatively affect the tissues. 
546 |a EN 
690 |a intense pulsed light 
690 |a oral biopsy 
690 |a thermal damage 
690 |a histological response 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Dentistry Journal, Vol 12, Iss 6, p 151 (2024) 
787 0 |n https://www.mdpi.com/2304-6767/12/6/151 
787 0 |n https://doaj.org/toc/2304-6767 
856 4 1 |u https://doaj.org/article/a0c5023ed43a4c9ab2c25f31f6eff4d3  |z Connect to this object online.