Feeding tube placement: auscultatory method and x-ray agreement

Objective: to evaluate the correlation between the auscultation test and X-ray when detecting the position of an enteral feeding tube. Methods: cross-sectional study in an intensive care unit in southern Brazil, in 2011. Clinical nurse and nurse researcher performed auscultation test recording the i...

Full description

Saved in:
Bibliographic Details
Main Authors: Mariur Gomes Beghetto (Author), Franciele Anziliero (Author), Dória Migotto Leães (Author), Elza Daniel de Mello (Author)
Format: Book
Published: Universidade Federal do Rio Grande do Sul.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_a10ec0ebadb04b2cb6ad01e2ba2bb2c9
042 |a dc 
100 1 0 |a Mariur Gomes Beghetto  |e author 
700 1 0 |a Franciele Anziliero  |e author 
700 1 0 |a Dória Migotto Leães  |e author 
700 1 0 |a Elza Daniel de Mello  |e author 
245 0 0 |a Feeding tube placement: auscultatory method and x-ray agreement 
260 |b Universidade Federal do Rio Grande do Sul. 
500 |a 1983-1447 
500 |a 10.1590/1983-1447.2015.04.54700 
520 |a Objective: to evaluate the correlation between the auscultation test and X-ray when detecting the position of an enteral feeding tube. Methods: cross-sectional study in an intensive care unit in southern Brazil, in 2011. Clinical nurse and nurse researcher performed auscultation test recording the impressions regarding the placement of an enteral feeding tube in 80 patients. A doctor evaluated the X-ray. Kappa coefficient and PABAK reviewed the agreements. Results: The X-ray showed that 70% of the enteral tubes were in the stomach, 27.4% in the duodenum, 1.3% in the esophagus, and 1.3% in the right lung. There was a weak correlation between clinical nurses and nurse researchers (PABAK = 0.054; P = 0.103), clinical nurses and X-rays (PABAK = 0.188; P = 0.111) and nurse researchers and X-rays (PABAK = 0.128; P = 0.107) . The auscultation test did not detect two risk conditions, enteral feeding tube in the esophagus and the bronchus. Conclusion: the auscultation test showed little agreement with the X-ray on the enteral feeding tube location. 
546 |a EN 
546 |a ES 
546 |a PT 
690 |a Auscultación 
690 |a Intubación gastrointestinal 
690 |a Enfermería 
690 |a Nursing 
690 |a RT1-120 
655 7 |a article  |2 local 
786 0 |n Revista Gaúcha de Enfermagem, Vol 36, Iss 4, Pp 98-103 
787 0 |n http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1983-14472015000400098&lng=en&tlng=en 
787 0 |n https://doaj.org/toc/1983-1447 
856 4 1 |u https://doaj.org/article/a10ec0ebadb04b2cb6ad01e2ba2bb2c9  |z Connect to this object online.