3-DIMENSIONAL ANALYSIS OF THE STRESS-STRAIN RELATION DURING ORTHODONTIC ANCHORAGE ON DENTAL IMPLANTS

This study uses the Finite Element Analysis (FEA) to investigate the stress-strain relation in peri-implant bone, caused by orthodontic anchorage. Materials and method. A tridimensional (3D) mathematical model was created to simulate the frontal teeth distalisation during anchorage on three dental i...

Full description

Saved in:
Bibliographic Details
Main Authors: Mihai A. Niculescu (Author), Cătălin Popescu (Author), Dan Păunescu (Author)
Format: Book
Published: Romanian Society of Oral Rehabilitation, 2015-04-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_a3bf1e94b1fb495e814adb322a6be0bc
042 |a dc 
100 1 0 |a Mihai A. Niculescu  |e author 
700 1 0 |a Cătălin Popescu  |e author 
700 1 0 |a Dan Păunescu  |e author 
245 0 0 |a 3-DIMENSIONAL ANALYSIS OF THE STRESS-STRAIN RELATION DURING ORTHODONTIC ANCHORAGE ON DENTAL IMPLANTS 
260 |b Romanian Society of Oral Rehabilitation,   |c 2015-04-01T00:00:00Z. 
500 |a 2066-7000 
500 |a 2601-4661 
520 |a This study uses the Finite Element Analysis (FEA) to investigate the stress-strain relation in peri-implant bone, caused by orthodontic anchorage. Materials and method. A tridimensional (3D) mathematical model was created to simulate the frontal teeth distalisation during anchorage on three dental implants. Using FEA was calculated the distribution of equivalent von-Mises stress when orthodontic forces of 2, 3 and 4 N were applied. ANSYS v11 software was properly configured for strain analysis in the model using FEA. Results and discussion. Periradicular maximum equivalent von-Mises stress values were 4,54 MPa for 2 N force, 6,82 MPa for 3 N force and 9 MPa when 4 N force was applied. Conclusions. FEA is a calculation method widely used in structural analysis that proved successfully in medical research. The forces caused by implant anchorage caused peri-implant bone stress in the model. The values of this stress correlated with the criterion of bone remodeling caused by mechanical load, and relative to study conditions, did not revealed biomechanical overload of periimplant bone structure 
546 |a EN 
690 |a finite element model 
690 |a orthodontic anchorage 
690 |a dental implant 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Romanian Journal of Oral Rehabilitation, Vol 7, Iss 1, Pp 38-44 (2015) 
787 0 |n http://www.rjor.ro/3-dimensional-analysis-of-the-stress-strain-relation-during-orthodontic-anchorage-on-dental-implants/?lang=ro 
787 0 |n https://doaj.org/toc/2066-7000 
787 0 |n https://doaj.org/toc/2601-4661 
856 4 1 |u https://doaj.org/article/a3bf1e94b1fb495e814adb322a6be0bc  |z Connect to this object online.