Anthropometric study of hand parameters for redesigning surgical instruments to combat ergonomic challenges in an operation theatre

Introduction: Anthropometric hand dimensions are used in the design of hand instruments for improving the efficiency and human comfort of surgical equipment and instruments. Instruments built for large male hands make it more difficult for petite female hands to operate them, which reduces their pro...

Full description

Saved in:
Bibliographic Details
Main Authors: Shikha Singh (Author), Dilshad Usmani (Author), Sanjeev Kumar Jain (Author), Saurabh Chaudhary (Author), Hina Nafees (Author)
Format: Book
Published: Occupational Health and Safety Society of Nepal, 2022-09-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_a3e07b8d18a04f92b918e17602dd2acd
042 |a dc 
100 1 0 |a Shikha Singh  |e author 
700 1 0 |a Dilshad Usmani  |e author 
700 1 0 |a Sanjeev Kumar Jain  |e author 
700 1 0 |a Saurabh Chaudhary  |e author 
700 1 0 |a Hina Nafees  |e author 
245 0 0 |a Anthropometric study of hand parameters for redesigning surgical instruments to combat ergonomic challenges in an operation theatre 
260 |b Occupational Health and Safety Society of Nepal,   |c 2022-09-01T00:00:00Z. 
500 |a 2738-9707 
500 |a 2091-0878 
520 |a Introduction: Anthropometric hand dimensions are used in the design of hand instruments for improving the efficiency and human comfort of surgical equipment and instruments. Instruments built for large male hands make it more difficult for petite female hands to operate them, which reduces their productivity and increases the risk of musculoskeletal diseases. So, the present study was undertaken to evaluate the differences in anthropometric and biomechanical parameters between the dominant hands of adult Indian males and females. Methods: The study was conducted on 335 Indian health care professionals of which 168 were males and 167 were females. Various anthropometric and biomechanical parameters were measured on the dominant hand of all the individuals included in the study. Length, breadth and span of a hand, as well as wrist circumference, were measured by measuring tape while handgrip strength and pinch strength was recorded by Jamar dynamometer & Jamar pinch gauge respectively. Obtained data were analyzed by applying the t-test SPSS version 27. We considered P-value <0.05 as statistically significant. Results: A higher statistically significant difference (<0.05) was found in hand anthropometric and biomechanical parameters amongst dominant hands of Indian male and female health care professionals. Conclusion: The present study was gender-based. All the anthropometric and biomechanical parameters were found to be of dimensions in males as compared to females. This study provides baseline anthropometric & biomechanical values of the Indian hand that will help manufacturers to redesign instruments to improve efficiency and prevent the risk of musculoskeletal disorders amongst health care professionals. 
546 |a EN 
690 |a hand anthropometry 
690 |a handgrip strength 
690 |a pinch strength 
690 |a Public aspects of medicine 
690 |a RA1-1270 
655 7 |a article  |2 local 
786 0 |n International Journal of Occupational Safety and Health, Vol 12, Iss 4 (2022) 
787 0 |n https://nepjol.info/index.php/IJOSH/article/view/43756 
787 0 |n https://doaj.org/toc/2738-9707 
787 0 |n https://doaj.org/toc/2091-0878 
856 4 1 |u https://doaj.org/article/a3e07b8d18a04f92b918e17602dd2acd  |z Connect to this object online.