The effects of implant-macro design on stress quantity and distribution around three types of fixtures by photo-elastic analysis

"nBackground and Aims: Considering the great incidence of implant failures due to high stresses around implant and at bone-implant interfaces, the aim of this study was to compare the effects of three different implant-macro designs on the quantity and distribution pattern of stresses around im...

Full description

Saved in:
Bibliographic Details
Main Authors: Shams Ak (Author), Eyvaz ziaee A (Author), Esfahanizadeh G (Author), Ghoseiri R (Author)
Format: Book
Published: Tehran University of Medical Sciences, 2011-04-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_a41eeb896d2b4ea9a5a1707b4e2edcb9
042 |a dc 
100 1 0 |a Shams Ak  |e author 
700 1 0 |a Eyvaz ziaee A  |e author 
700 1 0 |a Esfahanizadeh G  |e author 
700 1 0 |a Ghoseiri R  |e author 
245 0 0 |a The effects of implant-macro design on stress quantity and distribution around three types of fixtures by photo-elastic analysis 
260 |b Tehran University of Medical Sciences,   |c 2011-04-01T00:00:00Z. 
500 |a 1024-641X 
500 |a 2008-2444 
520 |a "nBackground and Aims: Considering the great incidence of implant failures due to high stresses around implant and at bone-implant interfaces, the aim of this study was to compare the effects of three different implant-macro designs on the quantity and distribution pattern of stresses around implants."nMaterials and Methods: In this experimental in vitro study, three types of implants including Biohorizon (4×10.5 mm), Iler (4×10 mm), and Swiss Plus (4.1×10 mm) were studied by applying photo-elastic method. The implants were placed within photo-elastic models with dimensions of 50×50×10 mm. Then through open tray impressed method, crowns for each implant were constructed and cemented. Vertical and oblique loads of 100 N and 150 N were applied on the cemented crowns within polariscope machine. Then the photographs were evaluated using Isochromatic Fringe Characteristics table."nResults: Under vertical loads of 100 N and 150 N, the values for Biohorizon, Iler, Swiss Plus fixtures at the cervical region were (2.35, 3.60) N, (2.50, 3.10) N, and (1.39, 2.35) N, respectively; and in apical region the values were (1.63, 2.35) N, (1.82, 2.35) N, and (2.50, 3.10) N. Under oblique loads, the measures at the cervical region were (4.00, 5.00) N, (1.82, 5.00) N, and (5.20, 6.00) N; and in apical region were "n(1.39, 2.00) N, (4.00, 2.35) N, and (2.35, 3.00) N, respectively for mentioned implants."nConclusion: Under vertical loads, the lowest cervical stresses were observed in Swiss Plus fixture and the lowest apical stress values were recorded for Biohorizon fixture. Under oblique loads, the lowest cervical stresses were found in Iler implant and lowest apical stresses were recorded for Bohorizon. 
546 |a FA 
690 |a Effect 
690 |a Implant 
690 |a Stress 
690 |a Distribution 
690 |a Medicine 
690 |a R 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Journal of Dental Medicine, Vol 24, Iss 2, Pp 77-86 (2011) 
787 0 |n http://journals.tums.ac.ir/PdfMed.aspx?pdf_med=/upload_files/pdf/18169.pdf&manuscript_id=18169 
787 0 |n https://doaj.org/toc/1024-641X 
787 0 |n https://doaj.org/toc/2008-2444 
856 4 1 |u https://doaj.org/article/a41eeb896d2b4ea9a5a1707b4e2edcb9  |z Connect to this object online.