Comparative study of single and multislice computed tomography for assessment of the mandibular canal

OBJECTIVE: The purpose of this study was to evaluate the accuracy of relative measurements from the roof of the mandibular canal to the alveolar crest in multislice (multidetector) computed tomography (MDCT) and single-slice computed tomography (SSCT). MATERIAL AND METHODS: The sample consisted of 2...

Full description

Saved in:
Bibliographic Details
Main Authors: Adriana da Silva Ferreira Paes (Author), Carla Ruffeil Moreira (Author), Marcelo Augusto Oliveira Sales (Author), Marcelo Gusmão Paraíso Cavalcanti (Author)
Format: Book
Published: University of São Paulo, 2007-06-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_a4e7d3b6d5ff499db76b45092d2fdb7f
042 |a dc 
100 1 0 |a Adriana da Silva Ferreira Paes  |e author 
700 1 0 |a Carla Ruffeil Moreira  |e author 
700 1 0 |a Marcelo Augusto Oliveira Sales  |e author 
700 1 0 |a Marcelo Gusmão Paraíso Cavalcanti  |e author 
245 0 0 |a Comparative study of single and multislice computed tomography for assessment of the mandibular canal 
260 |b University of São Paulo,   |c 2007-06-01T00:00:00Z. 
500 |a 10.1590/S1678-77572007000300012 
500 |a 1678-7757 
500 |a 1678-7765 
520 |a OBJECTIVE: The purpose of this study was to evaluate the accuracy of relative measurements from the roof of the mandibular canal to the alveolar crest in multislice (multidetector) computed tomography (MDCT) and single-slice computed tomography (SSCT). MATERIAL AND METHODS: The sample consisted of 26 printed CT films (7 SSCT and 19 MDCT) from the files of the LABI-3D (3D Imaging Laboratory) of the School of Dentistry of the University of São Paulo (FOUSP), which had been acquired using different protocols. Two observers analyzed in a randomized and independent order a series of 22 oblique CT reconstructions of each patient. Each observer analyzed the CT scans twice. The length of the mandibular canal and the distance between the mandibular canal roof and the crest of the alveolar ridge were obtained. Dahlberg test was used for statistical analysis. RESULTS: The mean error found for the mandibular canal length measurements obtained from SSCT was 0.53 mm in the interobserver analysis, and 0.38 mm for both observers. On MDCT images, the mean error was 0.0 mm in the interobserver analysis, and 0.0 and 0.23 mm in the intraobserver analysis. Regarding the distance between the mandibular canal roof and the alveolar bone crest, the SSCT images showed a mean error of 1.16 mm in the interobserver analysis and 0.66 and 0.59 mm in the intraobserver analysis. In the MDCT images, the mean error was 0.72 mm in the interobserver analysis and 0.50 and 0.54 mm in the intraobserver analysis. CONCLUSION: Multislice CT was demonstrated a more accurate method and demonstrated high reproducibility in the analysis of important anatomical landmarks for planning of mandibular dental implants, namely the mandibular canal pathway and alveolar crest height. 
546 |a EN 
690 |a X-ray computed tomography 
690 |a Dental Implants 
690 |a Mandibular nerve 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Journal of Applied Oral Science, Vol 15, Iss 3, Pp 220-224 (2007) 
787 0 |n http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572007000300012 
787 0 |n https://doaj.org/toc/1678-7757 
787 0 |n https://doaj.org/toc/1678-7765 
856 4 1 |u https://doaj.org/article/a4e7d3b6d5ff499db76b45092d2fdb7f  |z Connect to this object online.