Chairside 3-D printed impression trays: a new approach to increase the accuracy of conventional implant impression taking? An in vitro study

Abstract Purpose A high transfer accuracy of the intraoral implant position to a model is required, to manufacture implant-supported restorations. However, clinically relevant deviations persist between the intraoral implant position and the model obtained, even for the benchmark conventional custom...

Full description

Saved in:
Bibliographic Details
Main Authors: Alexander Schmidt (Author), Cara Berschin (Author), Bernd Wöstmann (Author), Maximiliane Amelie Schlenz (Author)
Format: Book
Published: SpringerOpen, 2023-12-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Abstract Purpose A high transfer accuracy of the intraoral implant position to a model is required, to manufacture implant-supported restorations. However, clinically relevant deviations persist between the intraoral implant position and the model obtained, even for the benchmark conventional custom implant impressions with polyether. Thus, new approaches using 3-D printed impression trays may increase the transfer accuracy of implant impressions. The ability to adjust parameters such as the thickness of the layers and the influence of the openings in the impression tray could potentially affect accuracy. Methods Four different types of impression trays (n = 10 for each group) for the conventional impression technique were investigated: conventional custom impression tray, customized foil tray, chairside 3-D printed impression tray with the SHERA system, and the Primeprint system using an implant master model with four implants in the posterior region and a reference cube. After plaster model casting, all models were measured using a coordinate measuring machine, and the deviation from the reference dataset was determined. A statistical ANOVA analysis was performed (p < 0.05). Results Chairside 3-D printed impression trays showed the best results, followed by conventional custom impression trays. Implant impressions obtained using a customized foil tray exhibited the lowest accuracy. Statistically significant differences were observed between 3-D printed impression trays and conventional custom impression and customized foil trays (p < 0.05). Whereas, the implant position did not have any significant influence on accuracy (p > 0.05). Conclusions Chairside 3-D printed impression trays significantly increase the transfer accuracy for implant impression taking. Graphical Abstract
Item Description:10.1186/s40729-023-00516-9
2198-4034