Effect of computer-aided design/computer-aided manufacturing bleach shade ceramic thickness on its light transmittance and microhardness of light-cured resin cement

Background: This study aimed to measure light transmittance (LT) through various thicknesses of computer-aided design/computer-aided manufacturing bleach shade ceramics and to assess the Vickers microhardness (VMH) of underlying light-cured resin cement. Materials and Methods: In this in vitro study...

Full description

Saved in:
Bibliographic Details
Main Authors: Pardis Sheibani (Author), Ghazaleh Ahmadizenous (Author), Behnaz Esmaeili (Author), Ali Bijani (Author)
Format: Book
Published: Wolters Kluwer Medknow Publications, 2024-06-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_a944b96d6c9a41a8b445b4b7afd0e91f
042 |a dc 
100 1 0 |a Pardis Sheibani  |e author 
700 1 0 |a Ghazaleh Ahmadizenous  |e author 
700 1 0 |a Behnaz Esmaeili  |e author 
700 1 0 |a Ali Bijani  |e author 
245 0 0 |a Effect of computer-aided design/computer-aided manufacturing bleach shade ceramic thickness on its light transmittance and microhardness of light-cured resin cement 
260 |b Wolters Kluwer Medknow Publications,   |c 2024-06-01T00:00:00Z. 
500 |a 1735-3327 
500 |a 2008-0255 
500 |a 10.4103/drj.drj_508_23 
520 |a Background: This study aimed to measure light transmittance (LT) through various thicknesses of computer-aided design/computer-aided manufacturing bleach shade ceramics and to assess the Vickers microhardness (VMH) of underlying light-cured resin cement. Materials and Methods: In this in vitro study, a total of 90 ceramic discs (VITA Mark II [VM], VITA Suprinity, and CELTRA Duo) were prepared in 0.5, 1, and 1.5 mm thicknesses. To measure LT, the Valo light-curing unit was placed in direct contact with the ceramics on the radiometer. The average LT was recorded after three measurements. In addition, 90 specimens of light-cured resin cement (Allcem Veneer) were cured in Teflon molds (0.5 mm in depth) beneath ceramic pieces. Ten specimens of resin cement were also cured without the presence of ceramic as a control group. VMH of the cement specimens was reported. The data were analyzed by one-way analysis of variance and multiple comparison tests (α =0.05) in SPSS version 17. Results: In each ceramic group, LT was negatively related to ceramic thickness (P < 0.05). At a thickness of 1.5 mm among all ceramic types, the VMH of resin cement was significantly decreased (P < 0.05). In all thicknesses, the VMH of resin cement was lower significantly than the control group, except for the thickness of 0.5 mm of VM. Conclusion: According to the results of this study, light-cured cement is not a suitable option for cementing the studied bleach shade ceramics. Furthermore, the thickness of the ceramic has a significant effect on LT (P < 0.05), unlike VMH. 
546 |a EN 
690 |a ceramics 
690 |a dental curing light 
690 |a hardness 
690 |a resin cements 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Dental Research Journal, Vol 21, Iss 1, Pp 44-44 (2024) 
787 0 |n https://journals.lww.com/10.4103/drj.drj_508_23 
787 0 |n https://doaj.org/toc/1735-3327 
787 0 |n https://doaj.org/toc/2008-0255 
856 4 1 |u https://doaj.org/article/a944b96d6c9a41a8b445b4b7afd0e91f  |z Connect to this object online.