The effect of different light-curing units on tensile strength and microhardness of a composite resin
The aim of this study was to evaluate the influence of different light-curing units on the tensile bond strength and microhardness of a composite resin (Filtek Z250 - 3M/ESPE). Conventional halogen (Curing Light 2500 - 3M/ESPE; CL) and two blue light emitting diode curing units (Ultraled - Dabi/Atla...
Saved in:
Main Authors: | , , |
---|---|
Format: | Book |
Published: |
University of São Paulo,
2007-12-01T00:00:00Z.
|
Subjects: | |
Online Access: | Connect to this object online. |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
MARC
LEADER | 00000 am a22000003u 4500 | ||
---|---|---|---|
001 | doaj_a9570b57dac54b1b83d6c8a7b69eada7 | ||
042 | |a dc | ||
100 | 1 | 0 | |a Eduardo Batista Franco |e author |
700 | 1 | 0 | |a Patrícia Aleixo dos Santos |e author |
700 | 1 | 0 | |a Rafael Francisco Lia Mondelli |e author |
245 | 0 | 0 | |a The effect of different light-curing units on tensile strength and microhardness of a composite resin |
260 | |b University of São Paulo, |c 2007-12-01T00:00:00Z. | ||
500 | |a 10.1590/S1678-77572007000600003 | ||
500 | |a 1678-7757 | ||
500 | |a 1678-7765 | ||
520 | |a The aim of this study was to evaluate the influence of different light-curing units on the tensile bond strength and microhardness of a composite resin (Filtek Z250 - 3M/ESPE). Conventional halogen (Curing Light 2500 - 3M/ESPE; CL) and two blue light emitting diode curing units (Ultraled - Dabi/Atlante; UL; Ultrablue IS - DMC; UB3 and UB6) were selected for this study. Different light intensities (670, 130, 300, and 600 mW/cm², respectively) and different curing times (20s, 40s and 60s) were evaluated. Knoop microhardness test was performed in the area corresponding to the fractured region of the specimen. A total of 12 groups (n=10) were established and the specimens were prepared using a stainless steel mold composed by two similar parts that contained a cone-shaped hole with two diameters (8.0 mm and 5.0 mm) and thickness of 1.0 mm. Next, the specimens were loaded in tensile strength until fracture in a universal testing machine at a crosshead speed of 0.5 mm/min and a 50 kg load cell. For the microhardness test, the same matrix was used to fabricate the specimens (12 groups; n=5). Microhardness was determined on the surfaces that were not exposed to the light source, using a Shimadzu HMV-2 Microhardness Tester at a static load of 50 g for 30 seconds. Data were analyzed statistically by two-way ANOVA and Tukey's test (p<0.05). Regarding the individual performance of the light-curing units, there was similarity in tensile strength with 20-s and 40-s exposure times and higher tensile strength when a 60-s light-activation time was used. Regarding microhardness, the halogen lamp had higher results when compared to the LED units. For all light-curing units, the variation of light-exposure time did not affect composite microhardness. However, lower irradiances needed longer light-activation times to produce similar effect as that obtained with high-irradiance light-curing sources. | ||
546 | |a EN | ||
690 | |a Photopolymerization | ||
690 | |a LED | ||
690 | |a Microhardness | ||
690 | |a Tensile strength | ||
690 | |a Dentistry | ||
690 | |a RK1-715 | ||
655 | 7 | |a article |2 local | |
786 | 0 | |n Journal of Applied Oral Science, Vol 15, Iss 6, Pp 470-474 (2007) | |
787 | 0 | |n http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572007000600003 | |
787 | 0 | |n https://doaj.org/toc/1678-7757 | |
787 | 0 | |n https://doaj.org/toc/1678-7765 | |
856 | 4 | 1 | |u https://doaj.org/article/a9570b57dac54b1b83d6c8a7b69eada7 |z Connect to this object online. |