Patient-reported outcomes with immediate-loaded two-implant-supported mandibular overdentures: Results of a 5-year prospective study

Background/purpose: Few studies have comprehensively assessed long-term patient-reported outcomes for overdentures supported by two immediate implants. The purpose of the study was to evaluate patient-reported outcomes of immediately loaded two-implant-supported overdentures retained by ball attachm...

Full description

Saved in:
Bibliographic Details
Main Authors: Yuriko Komagamine (Author), Manabu Kanazawa (Author), Daisuke Sato (Author), Maiko Iwaki (Author), Anna Miyayasu (Author), Shunsuke Minakuchi (Author)
Format: Book
Published: Elsevier, 2022-01-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Background/purpose: Few studies have comprehensively assessed long-term patient-reported outcomes for overdentures supported by two immediate implants. The purpose of the study was to evaluate patient-reported outcomes of immediately loaded two-implant-supported overdentures retained by ball attachments over a 5-year evaluation period. Material and methods: Nineteen participants with edentulous mandibles were provided with immediately loaded two-unsplinted-implant-supported overdentures retained by ball attachments. The participants completed the Japanese version of the Oral Health Impact Profile (OHIP)-EDENT-19 and the Patient's Denture Assessment (PDA). Additionally, patient satisfaction was measured by a 100-mm visual analog scale (VAS). Measurements were performed at baseline, and at 1 and 5 years following implant surgery. Results: Seventeen participants and 14 participants were evaluated at the 1-year and 5-year assessment, respectively. Considering the OHIP-EDENT-19, there was a significant decrease in the total (p = 0.046), "functional limitation" (p = 0.021), and "physical disability" (p = 0.034) scores at 1 year and the total (p = 0.045) and "physical disability" (p = 0.024) scores at 5 years following surgery, compared to the baseline scores. Considering the PDA, there was a significant increase in the "function" (p = 0.038) and "lower denture" (p = 0.003) scores at 1 year and the "function" (p = 0.032), "lower denture" (p = 0.008), and "esthetic and speech" (p = 0.043) scores at 5 years following surgery, compared to the baseline scores. Patient satisfaction at 1 year following surgery was significantly greater than that at baseline (p = 0.005). Conclusion: Immediately loaded two-unsplinted-implant-supported overdentures retained by ball attachments improved the oral health-related quality of life and self-assessment of dentures by the patients up to 5 years following implant surgery.
Item Description:1991-7902
10.1016/j.jds.2021.04.011