Effects of ultrasonic and high-speed air-driven devices on pulp-dentin reactions: An animal study

Background/purpose: The aim of this study was to evaluate the pulp-dentin response after pulp chamber perforation by ultrasonic and high-speed air-driven devices. Materials and methods: Eighteen upper incisors from nine dogs were used in this study. We prepared Class V cavity (3 × 5 mm) at the labia...

Full description

Saved in:
Bibliographic Details
Main Authors: Ming-Shu Lee (Author), Yen-Liang Chen (Author), Pei-Hsuan Huang (Author), Yu-Chih Chiang (Author), Hao-Hueng Chang (Author), Jeffrey Wu (Author), Chun-Pin Lin (Author)
Format: Book
Published: Elsevier, 2014-12-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Background/purpose: The aim of this study was to evaluate the pulp-dentin response after pulp chamber perforation by ultrasonic and high-speed air-driven devices. Materials and methods: Eighteen upper incisors from nine dogs were used in this study. We prepared Class V cavity (3 × 5 mm) at the labial side after anesthesia. The pulp was then exposed/perforated by either an ultrasonic or high-speed air-driven device. We evaluated the hemorrhage condition by stopping the bleeding with varying numbers of sponge pellets. Three observation time points were set: immediate, 1 week (1-wk), and 2 weeks (2-wk). Then, we evaluated the pulp-dentin response using scanning electronic microscopy (SEM) and histological examination. Results: The bleeding level caused by an ultrasonic device presented as either no bleeding or mild bleeding, and a high-speed air-driven bur caused worse bleeding conditions. The ultrasonic group showed better response in the immediate pulpal response. In 1 week, both methods presented no pulp necrosis, and those treated using the ultrasonic device presented with a regular odontoblastic layer under SEM observations. In the 2-wk group, both methods showed no pulp necrosis, whereas the high-speed device showed partial necrosis. SEM showed pulp tissue with lacerated wounds in those who had the high-speed device treatment. Conclusion: We conclude that the ultrasonic device causes less damage to the dental pulp tissue in comparison with the high-speed air-driven bur. Moreover, we expect that the ultrasonic device can be applied to vital pulp therapy-such as direct pulp capping, pulptotomy, or pulpectomy-due to its safe approach.
Item Description:1991-7902
10.1016/j.jds.2013.03.009