Effect of different torque settings selected during instrumentation on fracture strength of endodontically treated teeth

Background: The study evaluated the effect of root canal instrumentation at low and high torque settings on the fracture strength of endodontically treated teeth. Methods: Ninety extracted single-rooted human mandibular incisors were randomly divided into one control (CG) and two experimental groups...

Full description

Saved in:
Bibliographic Details
Main Authors: Demet Altunbaş (Author), Eda Gürsu (Author)
Format: Book
Published: Selçuk University, 2022-12-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_ab0bce7f68cf48c58cd42e0e7d24c19e
042 |a dc 
100 1 0 |a Demet Altunbaş  |e author 
700 1 0 |a Eda Gürsu  |e author 
245 0 0 |a Effect of different torque settings selected during instrumentation on fracture strength of endodontically treated teeth 
260 |b Selçuk University,   |c 2022-12-01T00:00:00Z. 
500 |a 2148-7529 
500 |a 10.15311/selcukdentj.1033713 
520 |a Background: The study evaluated the effect of root canal instrumentation at low and high torque settings on the fracture strength of endodontically treated teeth. Methods: Ninety extracted single-rooted human mandibular incisors were randomly divided into one control (CG) and two experimental groups (n=30): no instrumentation or filling (CG), instrumentation with ProTaper Universal files at low torque settings, and instrumentation with ProTaper Universal files at high torque settings. Root canal filling was performed with an epoxy resin-based sealer and gutta-percha using a single-cone technique in the experimental groups. Each specimen was tested for fracture strength. The analysis of variance and Tukey test were used to analyze the obtained data. The significance level was set at 0.05. Results: Statistically significant differences were observed between the groups (p = 0.001). While the difference between the CG and low torque groups was not significant (p > 0.05), the difference between the CG and high torque, low and high torque groups was significant (p < 0.05). Conclusion: According to this study results, since the lowest fracture strength value was observed in the high torque group, clinicians may be advised to choose the lowest torque settings recommended by the manufacturers for rotary systems. 
546 |a EN 
546 |a TR 
690 |a endodontics 
690 |a root canal preparation 
690 |a torque 
690 |a endodonti 
690 |a kök kanal preparasyonu 
690 |a tork 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Selcuk Dental Journal, Vol 9, Iss 3, Pp 851-855 (2022) 
787 0 |n https://dergipark.org.tr/tr/download/article-file/2120215 
787 0 |n https://doaj.org/toc/2148-7529 
856 4 1 |u https://doaj.org/article/ab0bce7f68cf48c58cd42e0e7d24c19e  |z Connect to this object online.