External Quality Assessment of Sputum Smear Microscopy in Tuberculosis Laboratories in Sughd, Tajikistan

Introduction: Tajikistan has a laboratory network with three levels of tuberculosis (TB) laboratories. The external quality assessment (EQA) of sputum smear microscopy was implemented in 2007. The objective of this study was to evaluate the EQA system and identify potential performance improvement s...

पूर्ण विवरण

में बचाया:
ग्रंथसूची विवरण
मुख्य लेखकों: Eva Chang (लेखक), Fabio Luelmo (लेखक), Zamira Baydulloeva (लेखक), Marija Joncevska (लेखक), Guljamol Kasymova (लेखक), Oktam Bobokhojaev (लेखक), Tom Mohr (लेखक)
स्वरूप: पुस्तक
प्रकाशित: University Library System, University of Pittsburgh, 2016-03-01T00:00:00Z.
विषय:
ऑनलाइन पहुंच:Connect to this object online.
टैग: टैग जोड़ें
कोई टैग नहीं, इस रिकॉर्ड को टैग करने वाले पहले व्यक्ति बनें!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_ab105f6ecc614865b6ddf9980c57e2e4
042 |a dc 
100 1 0 |a Eva Chang  |e author 
700 1 0 |a Fabio Luelmo  |e author 
700 1 0 |a Zamira Baydulloeva  |e author 
700 1 0 |a Marija Joncevska  |e author 
700 1 0 |a Guljamol Kasymova  |e author 
700 1 0 |a Oktam Bobokhojaev  |e author 
700 1 0 |a Tom Mohr  |e author 
245 0 0 |a External Quality Assessment of Sputum Smear Microscopy in Tuberculosis Laboratories in Sughd, Tajikistan 
260 |b University Library System, University of Pittsburgh,   |c 2016-03-01T00:00:00Z. 
500 |a 2166-7403 
500 |a 10.5195/cajgh.2015.230 
520 |a Introduction: Tajikistan has a laboratory network with three levels of tuberculosis (TB) laboratories. The external quality assessment (EQA) of sputum smear microscopy was implemented in 2007. The objective of this study was to evaluate the EQA system and identify potential performance improvement strategies in TB microscopic laboratories in Sughd, Tajikistan. Methods: This is a cross-sectional study based on retrospective record review and secondary data analyses on Acid-Fast Bacilli (AFB) microscopy data and EQA reading results collected between the first quarter of 2011 and the fourth quarter of 2013. Descriptive analyses were conducted to examine the overview of microscopy laboratories activities, EQA results, and laboratory performance. Result: Of the 123,874 smears examined between 2011 and 2013, 11,522 (9.30%) were re-checked by the EQA system. The population TB screening rate rose from 0.46% in 2011 to 0.57% in 2013, and the case positivity rate decreased from 6.98% to 4.80%. The regional EQA results showed a reduction in high false-positive, high false-negative, and low false-negative errors. False-positive errors had decreased from 0.13% in 2011 to 0.07% in 2013, and false-negative errors from 0.91% in 2011 to 0.15% in 2013. Regional sensitivity of smear microscopy, when compared to re-checking controller, increased from 88.2% in 2011 to 97.2% in 2013. The regional specificity level remained relatively stable at above 99%. Conclusion: Our study found that a decreasing trend of case positivity rate from 2011 to 2013 in Sughd, though the overall laboratory workload was on the rise. In addition, EQA results showed an overall error reduction and an improved sensitivity of smear microscopy in the region. The overview of microscopic laboratory activities and the actual evaluation of the EQA system on sputum smear microscopy complement each other in providing a better picture on the progress of TB laboratory strengthening. We recommend similar approaches to be adapted by future evaluations on TB microscopic laboratories, particularly among countries of high burden. Interactive training and feedback loops are crucial to improving TB surveillance in Tajikistan. 
546 |a EN 
690 |a external quality assessment 
690 |a tuberculosis 
690 |a sputum smeal microscopy 
690 |a Tajikistan 
690 |a Public aspects of medicine 
690 |a RA1-1270 
655 7 |a article  |2 local 
786 0 |n Central Asian Journal of Global Health, Vol 4, Iss 2 (2016) 
787 0 |n http://cajgh.pitt.edu/ojs/index.php/cajgh/article/view/230 
787 0 |n https://doaj.org/toc/2166-7403 
856 4 1 |u https://doaj.org/article/ab105f6ecc614865b6ddf9980c57e2e4  |z Connect to this object online.