Evaluation of effectiveness of intraoral delivery tip on single step impressions using monophase and two-phase impression materials: An in vivo study

Background and Rationale: The precise fit of prosthesis depends on the impression materials and the technique used. Addition silicone impression materials being the user-friendly material are used in monophase and two-phase techniques. Considering the paucity of data on the effectiveness of intraora...

Full description

Saved in:
Bibliographic Details
Main Authors: S Gowri (Author), V Shenoy (Author), S Kannan (Author)
Format: Book
Published: Wolters Kluwer Medknow Publications, 2015-01-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_ab5c2000a77c4473b9e60c5c4e470cbc
042 |a dc 
100 1 0 |a S Gowri  |e author 
700 1 0 |a V Shenoy  |e author 
700 1 0 |a S Kannan  |e author 
245 0 0 |a Evaluation of effectiveness of intraoral delivery tip on single step impressions using monophase and two-phase impression materials: An in vivo study 
260 |b Wolters Kluwer Medknow Publications,   |c 2015-01-01T00:00:00Z. 
500 |a 2249-4987 
500 |a 2394-2541 
500 |a 10.4103/2249-4987.160152 
520 |a Background and Rationale: The precise fit of prosthesis depends on the impression materials and the technique used. Addition silicone impression materials being the user-friendly material are used in monophase and two-phase techniques. Considering the paucity of data on the effectiveness of intraoral delivery tip (IODT) on void, tear and bubble formation using monophase impression technique in stock tray and two-phase impression technique in custom tray the present study was initiated. Materials and Methods: A total of 50 patients requiring single complete veneer crowns were enrolled. Monophase and two-phase impressions with and without IODT were made. Evaluation of the impression were made for tears, voids, and bubbles and alpha, beta, delta scores were given. Results: A significant reduction in the total number of voids was observed with two-phase technique either with or without IODT. No significant differences were observed in the proportion of overall evaluation into alpha, beta and delta between monophase and two-phase with and without IODT. No significant association was seen in the overall evaluation between the two groups (monophase and two-phase) as compared using Chi-square test for independency and a trend in association between overall evaluation as tested using Chi-square for linear trend analysis. Conclusion: Two-phase impression technique with the use of IODT produced decreased number of voids. 
546 |a EN 
690 |a Addition silicone 
690 |a bubble 
690 |a tear 
690 |a void 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Journal of Oral Research and Review, Vol 7, Iss 1, Pp 1-5 (2015) 
787 0 |n http://www.jorr.org/article.asp?issn=2249-4987;year=2015;volume=7;issue=1;spage=1;epage=5;aulast=Gowri 
787 0 |n https://doaj.org/toc/2249-4987 
787 0 |n https://doaj.org/toc/2394-2541 
856 4 1 |u https://doaj.org/article/ab5c2000a77c4473b9e60c5c4e470cbc  |z Connect to this object online.