Infrared thermographic evaluation of rise in temperature with conventional versus trephine drills

Aim: To compare the rise in temperature using trephines over conventional ones during bone site preparation. Setting and Design: An-vitro, evaluative study Materials and Methods: Twenty implant sites were prepared using pilot drill up to depth of 10 mm on bovine femoral bone. In first part, no irrig...

Full description

Saved in:
Bibliographic Details
Main Authors: Siddharth Gupta (Author), Ambika Shrivastava Gupta (Author), G S Chandu (Author), Shilpa Jain (Author)
Format: Book
Published: Wolters Kluwer Medknow Publications, 2021-01-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_ab9fa25f2bcc4791a23c4f45ecd2c949
042 |a dc 
100 1 0 |a Siddharth Gupta  |e author 
700 1 0 |a Ambika Shrivastava Gupta  |e author 
700 1 0 |a G S Chandu  |e author 
700 1 0 |a Shilpa Jain  |e author 
245 0 0 |a Infrared thermographic evaluation of rise in temperature with conventional versus trephine drills 
260 |b Wolters Kluwer Medknow Publications,   |c 2021-01-01T00:00:00Z. 
500 |a 0972-4052 
500 |a 1998-4057 
500 |a 10.4103/jips.jips_252_20 
520 |a Aim: To compare the rise in temperature using trephines over conventional ones during bone site preparation. Setting and Design: An-vitro, evaluative study Materials and Methods: Twenty implant sites were prepared using pilot drill up to depth of 10 mm on bovine femoral bone. In first part, no irrigation was used. Five sites were prepared using conventional drill of 2.8 mm, and other five were prepared with help of trephine drills. On completion of each drill, infrared thermometer was used to measure temperature on both the drill tip and the shaft. The same procedure was repeated with bone immersed in saline. Statistical Analysis Used: Student t test was used to evaluate the significance of difference. Result: Study showed that the temperature rise at drill tip was significantly higher for trephine drill (52.98 ± 1.67 °C) than conventional drills (48.20 ± 0.67 °C), however the temperature difference in trephine and conventional drills was statistically insignificant. Conclusion: The temperature increase was more distributed in conventional drills than trephine. Copious irrigation is thus mandatory for trephine drills. Intermittent drilling is preferred with conventional drills. 
546 |a EN 
690 |a conventional drills 
690 |a implant site 
690 |a irrigation 
690 |a temperature rise 
690 |a trephine drills 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n The Journal of Indian Prosthodontic Society, Vol 21, Iss 1, Pp 45-49 (2021) 
787 0 |n http://www.j-ips.org/article.asp?issn=0972-4052;year=2021;volume=21;issue=1;spage=45;epage=49;aulast=Gupta 
787 0 |n https://doaj.org/toc/0972-4052 
787 0 |n https://doaj.org/toc/1998-4057 
856 4 1 |u https://doaj.org/article/ab9fa25f2bcc4791a23c4f45ecd2c949  |z Connect to this object online.