How Many Microwave Disinfection Cycles is Safe for the Adaptability of Polymethyl Methacrylate (PMMA) Denture Base Materials?: An In Vitro Study

Introduction: We aimed to determine the maximum microwave disinfection cycles that is safe for the adaptability of polymethyl methacrylate (PMMA) denture bases under power-time setting of 630 W for 3 minutes. Materials and Methods: Thirty PMMA maxillary denture bases were constructed and divided int...

Full description

Saved in:
Bibliographic Details
Main Authors: Wan Nor Syariza Wan Ali (Author), Noor Farishahbanubinti Ahmad (Author), Sharifah Nor Aishah Syed Yussof (Author)
Format: Book
Published: Wolters Kluwer Medknow Publications, 2022-01-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_b5a1b1451fc7421f9e8c20c5965eaa89
042 |a dc 
100 1 0 |a Wan Nor Syariza Wan Ali  |e author 
700 1 0 |a Noor Farishahbanubinti Ahmad  |e author 
700 1 0 |a Sharifah Nor Aishah Syed Yussof  |e author 
245 0 0 |a How Many Microwave Disinfection Cycles is Safe for the Adaptability of Polymethyl Methacrylate (PMMA) Denture Base Materials?: An In Vitro Study 
260 |b Wolters Kluwer Medknow Publications,   |c 2022-01-01T00:00:00Z. 
500 |a 2155-8213 
500 |a 10.4103/denthyp.denthyp_97_21 
520 |a Introduction: We aimed to determine the maximum microwave disinfection cycles that is safe for the adaptability of polymethyl methacrylate (PMMA) denture bases under power-time setting of 630 W for 3 minutes. Materials and Methods: Thirty PMMA maxillary denture bases were constructed and divided into two groups, control (no disinfection) and test (microwave disinfection at 630W for 3 minutes in water immersion). Coltene Rapid Liner (Coltene/Whaledent AG, Altstatten, Switzerland) silicone was coated onto the internal surface of the samples followed by placement of 8 kgf of axial load. The silicone film was removed, and weighed using analytical balance. One day interval was given between each cycle and samples were stored in 37°C water bath. Tests were carried out until a statistically significant silicone film weight change detected. The data were analyzed on SPSS version 21.0 (IBM Corp, Armonk, NY). Results: Statistically significant change of the denture base was detected after the tenth cycle of microwave irradiation. Conclusion: The maximum microwave disinfection cycles that is safe for the adaptability of PMMA denture bases under power-time setting of 630 W for 3 minutes is only up to 10 cycles. 
546 |a EN 
690 |a acrylic denture base 
690 |a denture adaptability 
690 |a microwave disinfection 
690 |a polymethyl methacrylate 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Dental Hypotheses, Vol 13, Iss 3, Pp 99-102 (2022) 
787 0 |n http://www.dentalhypotheses.com/article.asp?issn=2155-8213;year=2022;volume=13;issue=3;spage=99;epage=102;aulast=Ali 
787 0 |n https://doaj.org/toc/2155-8213 
856 4 1 |u https://doaj.org/article/b5a1b1451fc7421f9e8c20c5965eaa89  |z Connect to this object online.