Dimensional stability of two impression materials after a 6-month storage period

Objective: Oral rehabilitation success is enhanced by an accurate and reproducible final impression. The purpose of this study is to evaluate the dimensional changes of a polyether and addition silicone subjected to disinfection and/or sterilization after a long storage period. Material and methods:...

Full description

Saved in:
Bibliographic Details
Main Authors: Francisco Martins (Author), Patrícia Branco (Author), José Reis (Author), Ignacio Barbero Navarro (Author), Paulo Maurício (Author)
Format: Book
Published: Medical Journals Sweden, 2017-01-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_b7f0cd7b78d34cdd97d0e10e89b226d6
042 |a dc 
100 1 0 |a Francisco Martins  |e author 
700 1 0 |a Patrícia Branco  |e author 
700 1 0 |a José Reis  |e author 
700 1 0 |a Ignacio Barbero Navarro  |e author 
700 1 0 |a Paulo Maurício  |e author 
245 0 0 |a Dimensional stability of two impression materials after a 6-month storage period 
260 |b Medical Journals Sweden,   |c 2017-01-01T00:00:00Z. 
500 |a 2333-7931 
500 |a 10.1080/23337931.2017.1401933 
520 |a Objective: Oral rehabilitation success is enhanced by an accurate and reproducible final impression. The purpose of this study is to evaluate the dimensional changes of a polyether and addition silicone subjected to disinfection and/or sterilization after a long storage period. Material and methods: Ninety samples were obtained from polyether ImpregumTM PentaTM (3M ESPETM, Seefeld, Germany) and 90 of addition silicone ImprintTM 4 PentaTM Putty (3M ESPETM, Seefeld, Germany) according to ISO 4823:2000. The samples of each material were split to form three groups with 30 samples each: a control group, a hypochlorite group (disinfection) and an autoclave group (sterilization). Samples were stored in the Portuguese Institute for Quality for six months at 23 °C. Samples were measured by laser interferometry, according to the Michelson technique before calculating dimensional stability according ISO 4823:2000. A statistical analysis via a three-way mixed ANOVA was performed. Results: Significant shrinkage of ImpregumTM PentaTM was 0.77 ± 0.17% in the control group, 0.42 ± 0.19% in the hypochlorite group and 0.52 ± 0.28% in the autoclave group. For ImprintTM 4 PentaTM Putty, the control group had a shrinkage of 0.42 ± 0.12%, the hypochlorite group 0.36 ± 0.09% and the autoclave group 0.59 ± 0.13%. Conclusions: The long-term storage of samples subjected to disinfection with 5.25% hypochlorite or autoclave sterilization can be used in a clinical setting as the dimensional changes are below the maximum permitted by the ISO 4823:2000, since there are no clinically significant changes in the dimension of the samples during the storage period. 
546 |a EN 
690 |a Elastomers 
690 |a sterilization 
690 |a laser interferometry 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Acta Biomaterialia Odontologica Scandinavica, Vol 3, Iss 1, Pp 84-91 (2017) 
787 0 |n http://dx.doi.org/10.1080/23337931.2017.1401933 
787 0 |n https://doaj.org/toc/2333-7931 
856 4 1 |u https://doaj.org/article/b7f0cd7b78d34cdd97d0e10e89b226d6  |z Connect to this object online.