Retention and penetration of a conventional resin-based sealant and a photochromatic flowable composite resin placed on occlusal pits and fissures

This study compares the retention and penetration of a conventional resin-based sealant (Fluroshield) and a photochromatic flowable composite resin (Tetric Flow Chroma) placed on occlusal pits and fissures and submitted to thermal or chemical cycling regimens. Penetration assessment - ten premolars...

Full description

Saved in:
Bibliographic Details
Main Authors: Aguilar F (Author), Drubi-Filho B (Author), Casemiro L (Author), Watanabe M.G.C (Author), Pires- (Author)
Format: Book
Published: Wolters Kluwer Medknow Publications, 2007-01-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_b8b6e67e4f1a4c57aeb1ca687f9e2817
042 |a dc 
100 1 0 |a Aguilar F  |e author 
700 1 0 |a Drubi-Filho B  |e author 
700 1 0 |a Casemiro L  |e author 
700 1 0 |a Watanabe M.G.C  |e author 
700 1 0 |a Pires-  |e author 
245 0 0 |a Retention and penetration of a conventional resin-based sealant and a photochromatic flowable composite resin placed on occlusal pits and fissures 
260 |b Wolters Kluwer Medknow Publications,   |c 2007-01-01T00:00:00Z. 
500 |a 0970-4388 
520 |a This study compares the retention and penetration of a conventional resin-based sealant (Fluroshield) and a photochromatic flowable composite resin (Tetric Flow Chroma) placed on occlusal pits and fissures and submitted to thermal or chemical cycling regimens. Penetration assessment - ten premolars were sealed with each material, isolated (except for the sealed surface) and immersed in 0.2&#x0025; Rhodamine B. The teeth were serially sectioned in a mesiodistal direction. The images of the sections were digitized and analyzed (ImageLab). The distance between the most superficial and the deepest points on the occlusal central groove was calculated to determine the groove&#x2032;s total depth. The length of the central groove filled with the sealant was divided by its total depth to obtain the percentage of sealing of the occlusal groove. Retention assessment - 30 premolars were sealed, their occlusal surfaces were photographed and the area occupied by the sealing materials was demarcated (ImageLab). The teeth were submitted to different treatments: thermocycled, stored in artificial saliva and immersed in acetic acid and saliva (10 cycles/day protocol for 30 days). New photographs were taken to assess the final area occupied by the materials. The difference between the final and initial area was calculated to obtain the material loss. The data was analyzed (two-way anova and Tukey&#x2032;s test <i> P</i> &lt; 0.05). Both materials presented similar penetration of the occlusal central groove. After thermal and chemical cycling, the materials did not differ with respect to retention, except for immersion in acetic acid. In this case, Tetric Flow Chroma presented greater retention than Fluoroshield. 
546 |a EN 
690 |a Flowable composite resin 
690 |a pit-and-fissure sealants 
690 |a retention 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Journal of Indian Society of Pedodontics and Preventive Dentistry, Vol 25, Iss 4, Pp 169-173 (2007) 
787 0 |n http://www.jisppd.com/article.asp?issn=0970-4388;year=2007;volume=25;issue=4;spage=169;epage=173;aulast=Aguilar 
787 0 |n https://doaj.org/toc/0970-4388 
856 4 1 |u https://doaj.org/article/b8b6e67e4f1a4c57aeb1ca687f9e2817  |z Connect to this object online.