Influence of the handrim diameter on heart rate and blood lactate in a world-class wheelchair athlete
The aim of the present study was focused on the determination of the effect of the diameter of the hand-rim of the racing wheelchair on the heart rate and blood lactate produced at the competition speeds. The study was carried out with a world-class athlete, that made a total of 9 series of 5 minute...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Book |
Published: |
Asociación Española de Ciencias del Deporte,
2010-09-01T00:00:00Z.
|
Subjects: | |
Online Access: | Connect to this object online. |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
MARC
LEADER | 00000 am a22000003u 4500 | ||
---|---|---|---|
001 | doaj_b9f7c4500e8b46d6ac1ec1c5f9143825 | ||
042 | |a dc | ||
100 | 1 | 0 | |a G. Brizuela |e author |
700 | 1 | 0 | |a M. Polo |e author |
700 | 1 | 0 | |a J. Martos |e author |
700 | 1 | 0 | |a E. Sanchis |e author |
245 | 0 | 0 | |a Influence of the handrim diameter on heart rate and blood lactate in a world-class wheelchair athlete |
260 | |b Asociación Española de Ciencias del Deporte, |c 2010-09-01T00:00:00Z. | ||
500 | |a 2386-4095 | ||
520 | |a The aim of the present study was focused on the determination of the effect of the diameter of the hand-rim of the racing wheelchair on the heart rate and blood lactate produced at the competition speeds. The study was carried out with a world-class athlete, that made a total of 9 series of 5 minutes, at maintained speed, recovering 10 min between series and testing 3 hand-rim (34, 36 and 38cm of diameter) at 3 different speeds (20, 22 and 24 Km/h). Heart rate and blood lactate was measured. An ANOVA was made and we found statistically significant differences (p <0.0001) on Heart Rate (HR), between the different speeds and between the different diameters of hand-rim. Besides that we also found significant interaction (p <0.0001) among the factors Speed and Diameter of hand-rim. In general terms it is possible to conclude that at 20 Km/h the most efficient hand-rim (minor HR and blood lactate) was the one of 36 cm, whereas the least efficient was the one of 34 cm. Both 22 and 24 Km/h the most efficient hand-rim was that of 34 cm whereas the least efficient was that of 38 cm. We can conclude that the election of the optimal diameter of hand-rim supposes such improvement in the mechanical efficiency that in case of the studied athlete, his maximum sustainable speed with the hand-rim of 36 cm would be about 23 Km/h whereas with the hand-rim of 34 cm would be 24 Km/h. KEY WORDS: Wheelchairs. Track and field. Mechanical efficiency. | ||
546 | |a EN | ||
690 | |a Sports | ||
690 | |a GV557-1198.995 | ||
690 | |a Sports medicine | ||
690 | |a RC1200-1245 | ||
655 | 7 | |a article |2 local | |
786 | 0 | |n European Journal of Human Movement, Vol 16 (2010) | |
787 | 0 | |n https://eurjhm.com/index.php/eurjhm/article/view/163 | |
787 | 0 | |n https://doaj.org/toc/2386-4095 | |
856 | 4 | 1 | |u https://doaj.org/article/b9f7c4500e8b46d6ac1ec1c5f9143825 |z Connect to this object online. |