Development of a 'drop-count' method for the screening of the ethanol content in hand sanitisers using oxalic acid and potassium permanganate titrimetry

Introduction The demand for ethanol-based sanitisers has increased dramatically since the dawn of the COVID-19 era, making it very difficult for health regulators to ensure the quality of the products and the safety of unsuspecting consumers. This article reports the development and application of a...

Full description

Saved in:
Bibliographic Details
Main Authors: Kaneoa E. Monts'o (Author), Rapelang Ts'emane (Author), Teboho E. Mpakanyane (Author), Selloane C. Masiloane-Bohloko (Author), Thato V. Ramashamole (Author), Mosotho George (Author)
Format: Book
Published: Orapuh, Inc., 2022-07-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_ba25014ad04b4b34a0e58c2e4fed997f
042 |a dc 
100 1 0 |a Kaneoa E. Monts'o  |e author 
700 1 0 |a Rapelang Ts'emane   |e author 
700 1 0 |a Teboho E. Mpakanyane   |e author 
700 1 0 |a Selloane C. Masiloane-Bohloko  |e author 
700 1 0 |a Thato V. Ramashamole   |e author 
700 1 0 |a Mosotho George  |e author 
245 0 0 |a Development of a 'drop-count' method for the screening of the ethanol content in hand sanitisers using oxalic acid and potassium permanganate titrimetry 
260 |b Orapuh, Inc.,   |c 2022-07-01T00:00:00Z. 
500 |a 10.4314/orapj.v3i1.1 
500 |a 2644-3740 
520 |a Introduction The demand for ethanol-based sanitisers has increased dramatically since the dawn of the COVID-19 era, making it very difficult for health regulators to ensure the quality of the products and the safety of unsuspecting consumers. This article reports the development and application of a simple 'drop-count' titrimetry method for the determination of ethanol in hand sanitisers. Materials and Methods This method follows the classical potassium permanganate-oxalic acid titrimetry but uses very small volumes of the reagents - 0.5 mL of ethanol sample solution, 6 mL of acidified 0.1 M potassium permanganate, and a few counted drops of 0.1M oxalic acid. Results This method achieved satisfactory figures of merit, namely, linearity (R2 ≥ 0.9667), reproducibility, and importantly very little matrix effect in the alcohol concentration range of 50 to 80%. Conclusion The small volumes (< 10 mL in total) of the reagents required make this method considerably safe and cost-effective and applicable for fieldwork even by untrained personnel, not just chemists as is often the case for field applications. 
546 |a EN 
690 |a COVID-19 
690 |a drop-count 
690 |a ethanol 
690 |a hand sanitiser 
690 |a oxalic acid 
690 |a potassium permanganate 
690 |a Internal medicine 
690 |a RC31-1245 
690 |a Medicine (General) 
690 |a R5-920 
655 7 |a article  |2 local 
786 0 |n Orapuh Journal, Vol 3, Iss 1 (2022) 
787 0 |n https://www.orapuh.org/ojs/ojs-3.1.2-4/index.php/orapj/article/view/94 
787 0 |n https://doaj.org/toc/2644-3740 
856 4 1 |u https://doaj.org/article/ba25014ad04b4b34a0e58c2e4fed997f  |z Connect to this object online.