Graftless solution for multiple unfavorably placed implants using dynamic abutment® solutions: A case report with a 3-year follow-up

The employment of implant-supported crowns and bridges has become a well-established and preferred approach in replacing missing teeth. A favorable implant position is mandatory to obtain good esthetic results and ideal emergence of screw access hole. Usually, unfavorably placed implants are the res...

Full description

Saved in:
Bibliographic Details
Main Authors: Chandrasekhar Nakka (Author), Soujanya Kollipara (Author), Kothuri Naga Ravalika (Author)
Format: Book
Published: Wolters Kluwer Medknow Publications, 2020-01-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_bb872c63c49c41dc857f4e1be93c0e0d
042 |a dc 
100 1 0 |a Chandrasekhar Nakka  |e author 
700 1 0 |a Soujanya Kollipara  |e author 
700 1 0 |a Kothuri Naga Ravalika  |e author 
245 0 0 |a Graftless solution for multiple unfavorably placed implants using dynamic abutment® solutions: A case report with a 3-year follow-up 
260 |b Wolters Kluwer Medknow Publications,   |c 2020-01-01T00:00:00Z. 
500 |a 0972-4052 
500 |a 1998-4057 
500 |a 10.4103/jips.jips_362_19 
520 |a The employment of implant-supported crowns and bridges has become a well-established and preferred approach in replacing missing teeth. A favorable implant position is mandatory to obtain good esthetic results and ideal emergence of screw access hole. Usually, unfavorably placed implants are the result of insufficient bone volume which leads to implant trajectory in the available bone. Once placed, they are restored giving a cement-retained prosthesis to avoid labial/buccal screw access holes. A graftless solution for this scenario may be using an angulated screw channel technology which corrects the prosthetic screw access hole emergence in an alternative direction which is more esthetic and acceptable. Dynamic Abutment® Solutions system is unique and exclusive and can be used as a true alternative to titanium-angulated abutments or customized Ti abutments designed through computer-aided design and computer-aided manufacturing technologies. The Dynamic Abutment® solutions system rectifies angulation issues with millimetric precision up to 30° with full freedom of movement. This case report explains a case where a two-implant supported fixed partial denture was employed in the esthetic zone using Dynamic Abutment® Solutions system with angulation rectification by a graftless procedure. 
546 |a EN 
690 |a angulated screw channel 
690 |a computer-aided design and computer-aided manufacturing 
690 |a dental implants 
690 |a graftless 
690 |a screw retained 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n The Journal of Indian Prosthodontic Society, Vol 20, Iss 3, Pp 331-334 (2020) 
787 0 |n http://www.j-ips.org/article.asp?issn=0972-4052;year=2020;volume=20;issue=3;spage=331;epage=334;aulast=Nakka 
787 0 |n https://doaj.org/toc/0972-4052 
787 0 |n https://doaj.org/toc/1998-4057 
856 4 1 |u https://doaj.org/article/bb872c63c49c41dc857f4e1be93c0e0d  |z Connect to this object online.