In Newborn Infants a New Intubation Method May Reduce the Number of Intubation Attempts: A Randomized Pilot Study

Severe desaturation or bradycardia often occur during neonatal endotracheal intubation. Using continuous gas flow through the endotracheal tube might reduce the incidence of these events. We hypothesized that continuous gas flow through the endotracheal tube during nasotracheal intubation compared t...

Full description

Saved in:
Bibliographic Details
Main Authors: Marlies Bruckner (Author), Nicholas M. Morris (Author), Gerhard Pichler (Author), Christina H. Wolfsberger (Author), Stefan Heschl (Author), Lukas P. Mileder (Author), Bernhard Schwaberger (Author), Georg M. Schmölzer (Author), Berndt Urlesberger (Author)
Format: Book
Published: MDPI AG, 2021-06-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_bc953ac7d9e54ad99e1d28d97c70a733
042 |a dc 
100 1 0 |a Marlies Bruckner  |e author 
700 1 0 |a Nicholas M. Morris  |e author 
700 1 0 |a Gerhard Pichler  |e author 
700 1 0 |a Christina H. Wolfsberger  |e author 
700 1 0 |a Stefan Heschl  |e author 
700 1 0 |a Lukas P. Mileder  |e author 
700 1 0 |a Bernhard Schwaberger  |e author 
700 1 0 |a Georg M. Schmölzer  |e author 
700 1 0 |a Berndt Urlesberger  |e author 
245 0 0 |a In Newborn Infants a New Intubation Method May Reduce the Number of Intubation Attempts: A Randomized Pilot Study 
260 |b MDPI AG,   |c 2021-06-01T00:00:00Z. 
500 |a 10.3390/children8070553 
500 |a 2227-9067 
520 |a Severe desaturation or bradycardia often occur during neonatal endotracheal intubation. Using continuous gas flow through the endotracheal tube might reduce the incidence of these events. We hypothesized that continuous gas flow through the endotracheal tube during nasotracheal intubation compared to standard nasotracheal intubation will reduce the number of intubation attempts in newborn infants. In a randomized controlled pilot study, neonates were either intubated with continuous gas flow through the endotracheal tube during intubation (intervention group) or no gas flow during intubation (control group). Recruitment was stopped early due to financial and organizational issues. A total of 16 infants and 39 intubation attempts were analyzed. The median (interquartile range) number of intubation attempts and number of abandoned intubations due to desaturation and/or bradycardia were 1 (1-2) and 4 (2-5), (<i>p</i> = 0.056) and <i>n</i> = 3 versus <i>n</i> = 20, (<i>p</i> = 0.060) in the intervention group and control group, respectively. Continuous gas flow through the endotracheal tube during intubation seems to be favorable and there are no major unexpected adverse consequences of attempting this methodology. 
546 |a EN 
690 |a intubation 
690 |a endotracheal tube 
690 |a ventilation 
690 |a acute respiratory failure 
690 |a desaturation 
690 |a neonatal intensive care unit 
690 |a Pediatrics 
690 |a RJ1-570 
655 7 |a article  |2 local 
786 0 |n Children, Vol 8, Iss 7, p 553 (2021) 
787 0 |n https://www.mdpi.com/2227-9067/8/7/553 
787 0 |n https://doaj.org/toc/2227-9067 
856 4 1 |u https://doaj.org/article/bc953ac7d9e54ad99e1d28d97c70a733  |z Connect to this object online.