Effect of the Application Procedure on The Bond Strength of Universal Adhesive in Restoration Repair

Objective: This study aimed to evaluate the effect of reduced application time on the bond strength of a universal adhesive used for the repair of hybrid ceramic and composite resin restorations.Methods: In the study, a total of 48 rectangular prisms of sizes 7×6×2 mm hybrid ceramic (Vita Enamic, Za...

Full description

Saved in:
Bibliographic Details
Main Authors: Beyza Gül (Author), Fatma Keçeci (Author), Hüseyin Hatirli (Author), Gülşah Tonga (Author)
Format: Book
Published: Atatürk University, 2024-07-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_bed3eba8024f43c3b4e3e81f7fc231b8
042 |a dc 
100 1 0 |a Beyza Gül  |e author 
700 1 0 |a Fatma Keçeci  |e author 
700 1 0 |a Hüseyin Hatirli  |e author 
700 1 0 |a Gülşah Tonga  |e author 
245 0 0 |a Effect of the Application Procedure on The Bond Strength of Universal Adhesive in Restoration Repair 
260 |b Atatürk University,   |c 2024-07-01T00:00:00Z. 
500 |a 2822-2555 
500 |a 10.17567/currresdentsci.1520323 
520 |a Objective: This study aimed to evaluate the effect of reduced application time on the bond strength of a universal adhesive used for the repair of hybrid ceramic and composite resin restorations.Methods: In the study, a total of 48 rectangular prisms of sizes 7×6×2 mm hybrid ceramic (Vita Enamic, Zahnfabrik, Germany) and composite resin (Solare X, GC, Japan) specimens were prepared. All samples were aged with 5000 thermal cycles. Then, the upper surfaces of the samples were roughened with a diamond fissure bur (10-36µ, 852 FG Meisinger; Hager & Meisinger GmbH, Germany) with 5 strokes under water cooling. The samples were divided into 2 subgroups according to the different application times of the adhesive system (G-Premio Bond, GC, Japan) (n=12). Then, composite resin (Solare X, GC) was placed using plastic cylinder molds with 3 mm inner diameter and height and cured with light for 20 seconds. All samples were thermal aged and then a shear bond strength test was conducted. The data were analyzed with Two-way ANOVA and post-hoc Tukey HSD tests (p˂0,05).Results: Two-way ANOVA revealed that the repair bond strength of the 10 seconds of waiting was significantly higher than the quick application for both hybrid ceramic and composite resin (p˂0,05). It was determined that there was no significant difference between hybrid ceramic and composite resin in the both quick application group and 10 seconds waiting group (p˃0,05).Conclusion: Quick application procedure showed lower shear bond strength than 10 seconds waiting group for the repair of both composite resin and hybrid ceramic (p<0,05).Keywords:Quick application, Application time, Universal adhesive, restoration repair.. 
546 |a EN 
546 |a TR 
690 |a quick application 
690 |a application time 
690 |a universal adhesive 
690 |a restoration repai 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Current Research in Dental Sciences, Vol 34, Iss 3, Pp 160-165 (2024) 
787 0 |n https://dergipark.org.tr/tr/download/article-file/4088470 
787 0 |n https://doaj.org/toc/2822-2555 
856 4 1 |u https://doaj.org/article/bed3eba8024f43c3b4e3e81f7fc231b8  |z Connect to this object online.