The accuracy of placental alpha-microglobuline-1 test in diagnosis of premature rupture of the membranes

Background: Premature rupture of membranes (PROM) is a common obstetric issue during pregnancy which might lead to serious fetal or maternal problems. Therefore, an appropriate diagnosis and management of PROM are of significant importance in patients. Objective: The aim of this study was to determi...

Full description

Saved in:
Bibliographic Details
Main Authors: Maryam Khooshideh (Author), Vida Radi (Author), Reihaneh Hosseini (Author), Ladan Hosseini (Author)
Format: Book
Published: Shahid Sadoughi University of Medical Science, Yazd, Iran, 2015-06-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_bf6f314bc862403bae6c4b5ba045bf8f
042 |a dc 
100 1 0 |a Maryam Khooshideh  |e author 
700 1 0 |a Vida Radi  |e author 
700 1 0 |a Reihaneh Hosseini  |e author 
700 1 0 |a Ladan Hosseini  |e author 
245 0 0 |a The accuracy of placental alpha-microglobuline-1 test in diagnosis of premature rupture of the membranes 
260 |b Shahid Sadoughi University of Medical Science, Yazd, Iran,   |c 2015-06-01T00:00:00Z. 
500 |a 1680-6433 
500 |a 2008-2177 
520 |a Background: Premature rupture of membranes (PROM) is a common obstetric issue during pregnancy which might lead to serious fetal or maternal problems. Therefore, an appropriate diagnosis and management of PROM are of significant importance in patients. Objective: The aim of this study was to determine the accuracy of placental alpha microglobuline-1 (PAMG-1) test in PROM diagnosis and compare this diagnostic method with other standard tests in diagnosis of PROM. Materials and Methods: In this prospective diagnostic accuracy study, patients with symptoms of membrane rupture in 16-39 weeks of gestation were involved. Three tests including Fern, Nitrazine and PAMG-1 were performed at the same time. Results: PROM was confirmed in 86 patients out of 100. The sensitivity and specificity were respectively 81.3% and 100% for Fern test, 93% and 92.8% for Nitrazine test, 98.9% and 92.8% for PAMG-1 test. PAMG-1 test showed higher sensitivity (98.9% with p<0.001) and accuracy (98%) compared with conventional tests. Although PAMG-1showed a lower positive predictive value (PPV) compared to conventional tests such as Fern test (100%), it was shown to be more accurate. Conclusion: The accuracy of PAMG-1 test was superior to both Fern and Nitrazine test in PROM diagnosis. 
546 |a EN 
690 |a Gynecology and obstetrics 
690 |a RG1-991 
690 |a Reproduction 
690 |a QH471-489 
655 7 |a article  |2 local 
786 0 |n Iranian Journal of Reproductive Medicine, Vol 13, Iss 6, Pp 355-360 (2015) 
787 0 |n http://www.ssu.ac.ir/ijrm/index.php/ijrm/article/view/1551/862 
787 0 |n https://doaj.org/toc/1680-6433 
787 0 |n https://doaj.org/toc/2008-2177 
856 4 1 |u https://doaj.org/article/bf6f314bc862403bae6c4b5ba045bf8f  |z Connect to this object online.