A morphometric study of acromion process of scapula and its clinical significance

Objective: The acromion process is associated with a variety of ailments in the shoulder. Therefore, the aim of this study was to record and study all the morphometric values of the acromion process and its morphological features. Materials and Methods: The study was carried out on 50 unpaired dried...

Полное описание

Сохранить в:
Библиографические подробности
Главные авторы: Chandni Gupta (Автор), Abhilasha Priya (Автор), Sneha Guruprasad Kalthur (Автор), Antony Sylvan D'Souza (Автор)
Формат:
Опубликовано: Wolters Kluwer Medknow Publications, 2014-01-01T00:00:00Z.
Предметы:
Online-ссылка:Connect to this object online.
Метки: Добавить метку
Нет меток, Требуется 1-ая метка записи!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_c1618e15f4fe48d1bf2137e4e9667cd3
042 |a dc 
100 1 0 |a Chandni Gupta  |e author 
700 1 0 |a Abhilasha Priya  |e author 
700 1 0 |a Sneha Guruprasad Kalthur  |e author 
700 1 0 |a Antony Sylvan D'Souza  |e author 
245 0 0 |a A morphometric study of acromion process of scapula and its clinical significance 
260 |b Wolters Kluwer Medknow Publications,   |c 2014-01-01T00:00:00Z. 
500 |a 2348-3334 
500 |a 2348-506X 
500 |a 10.4103/2348-3334.138885 
520 |a Objective: The acromion process is associated with a variety of ailments in the shoulder. Therefore, the aim of this study was to record and study all the morphometric values of the acromion process and its morphological features. Materials and Methods: The study was carried out on 50 unpaired dried scapulae. The length, width, and thickness of the acromion process were measured, and the length and width of scapula was also measured using vernier calipers. The acromiocoracoid and acromioglenoid distances were also measured. The shape, type of acromion process, and the presence of enthesophytes were noted and whether the anterior 2/3 rd of inferior surface of acromion process is rough or smooth was also noted. Results: The mean length, width, and thickness of acromion process were 4.21, 2.42, and 0.73 cm, respectively. The mean length and width of scapula were 13.93 and 10.14 cm, respectively. The mean acromiocoracoid distance and acromioglenoid distance were 3.09 and 2.47 cm, respectively. The most common shape of the acromion process noted was quadrangular in 40% of scapulae. In 90% of scapulae, the anterior 2/3 rd of inferior surface was rough and in 80% scapulae, enthesophytes were present. Conclusions: This study will help the clinicians in understanding and curing various shoulder joint disorders. 
546 |a EN 
690 |a Acromion 
690 |a measurements 
690 |a rotator cuff 
690 |a shape 
690 |a type 
690 |a Medicine 
690 |a R 
690 |a Nursing 
690 |a RT1-120 
655 7 |a article  |2 local 
786 0 |n CHRISMED Journal of Health and Research, Vol 1, Iss 3, Pp 164-169 (2014) 
787 0 |n http://www.cjhr.org/article.asp?issn=2348-3334;year=2014;volume=1;issue=3;spage=164;epage=169;aulast=Gupta 
787 0 |n https://doaj.org/toc/2348-3334 
787 0 |n https://doaj.org/toc/2348-506X 
856 4 1 |u https://doaj.org/article/c1618e15f4fe48d1bf2137e4e9667cd3  |z Connect to this object online.