Evaluating the Implant Stability of Titanium Prepared Platelet Rich Fibrin Treated Periimplant Osseous Defects with Resonance Frequency Analysis
Objective: In this study, we aimed to determine periimplantal tissue regeneration in the use of platelet-rich fibrin in periimplantal defects. Methods:Twelve male New Zealand white rabbits were used for this study. each of the right and left tibias of rabbits Using a trephine bur (diameter 7.0 mm)...
Saved in:
Main Authors: | , |
---|---|
Format: | Book |
Published: |
Cumhuriyet University,
2016-12-01T00:00:00Z.
|
Subjects: | |
Online Access: | Connect to this object online. |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
MARC
LEADER | 00000 am a22000003u 4500 | ||
---|---|---|---|
001 | doaj_c1b9718e67dd4f6d93e734bf6d785f0f | ||
042 | |a dc | ||
100 | 1 | 0 | |a Turan Emre Kuzu |e author |
700 | 1 | 0 | |a Hakan Özdemir |e author |
245 | 0 | 0 | |a Evaluating the Implant Stability of Titanium Prepared Platelet Rich Fibrin Treated Periimplant Osseous Defects with Resonance Frequency Analysis |
260 | |b Cumhuriyet University, |c 2016-12-01T00:00:00Z. | ||
500 | |a 1302-5805 | ||
500 | |a 2146-2852 | ||
520 | |a Objective: In this study, we aimed to determine periimplantal tissue regeneration in the use of platelet-rich fibrin in periimplantal defects. Methods:Twelve male New Zealand white rabbits were used for this study. each of the right and left tibias of rabbits Using a trephine bur (diameter 7.0 mm), monocortical defects were prepared (7 mm width,4 mm depth).Subsequently, dental implants(AL-Technology dental implants sharkimplants) were installed into the left and right tibia (diameter 3.0 mm, length 8 mm). In the experimental groups, the peri-implant defect was filled respectively 1-autogenous grafts, 2-PRF 3-synthetic grafts (MIS 4BONE ). The control was left in an unfilled state. İmplant stability was evaluated with the resonance frequency analysis method (RFA)Results: The Ostell ISQ for the experimental groups respectively 1 -autogenous graft group 76.00±3.89,2-PRF group 75.00±3.84,3- sentetic graft group 67.00±5.72 while control group 56,33±5,12. The difference between the 2 groups (autogenous graft and prf groups) was statistically not significant while all other differences between groups are statistically significant.Conclusion: Within the limits of this study, it was found that periimplantal defects in the regeneration of Platelet-Rich Fibrin is effective as the autogenous graft | ||
546 | |a EN | ||
690 | |a platelet rich fibrin | ||
690 | |a periimplantal defect | ||
690 | |a resonance frequency analysis. | ||
690 | |a Dentistry | ||
690 | |a RK1-715 | ||
655 | 7 | |a article |2 local | |
786 | 0 | |n Cumhuriyet Dental Journal, Vol 19, Iss 2, Pp 154-165 (2016) | |
787 | 0 | |n https://dergipark.org.tr/tr/download/article-file/261264 | |
787 | 0 | |n https://doaj.org/toc/1302-5805 | |
787 | 0 | |n https://doaj.org/toc/2146-2852 | |
856 | 4 | 1 | |u https://doaj.org/article/c1b9718e67dd4f6d93e734bf6d785f0f |z Connect to this object online. |