Diagnostic value of BIRADS method using sonography in evaluating the level of malignancy of breast masses compared with biopsy

Introduction: Ultrasound is a valuable diagnostic imaging modality in the clinical evaluation of breast masses. BIRADS (Breast Imaging Reporting and Data System) classification in ultrasound is an important and reliable method for assessment and estimation of the risk of malignancy in breast lesions...

Full description

Saved in:
Bibliographic Details
Main Authors: Donya Farrokh (Author), Seyyed Ali Alamdaran (Author), Ali Feizy (Author), Hamed Soleimany (Author)
Format: Book
Published: Mashhad University of Medical Sciences, 2019-08-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_c4026b5122544214922171d58ceef0fc
042 |a dc 
100 1 0 |a Donya Farrokh  |e author 
700 1 0 |a Seyyed Ali Alamdaran  |e author 
700 1 0 |a Ali Feizy  |e author 
700 1 0 |a Hamed Soleimany  |e author 
245 0 0 |a Diagnostic value of BIRADS method using sonography in evaluating the level of malignancy of breast masses compared with biopsy 
260 |b Mashhad University of Medical Sciences,   |c 2019-08-01T00:00:00Z. 
500 |a 1680-2993 
500 |a 2008-2363 
500 |a 10.22038/ijogi.2019.13738 
520 |a Introduction: Ultrasound is a valuable diagnostic imaging modality in the clinical evaluation of breast masses. BIRADS (Breast Imaging Reporting and Data System) classification in ultrasound is an important and reliable method for assessment and estimation of the risk of malignancy in breast lesions. This study was performed with aim to evaluate the accuracy of the results of BIRADS classification (Grade 3 and 4) using sonography in evaluating the level of malignancy of breast masses and comparing it with pathology results. Methods: This study was performed on 139 patients referred to Imam Reza hospital, Omid Oncology hospital and some private clinics in Mashhad and evaluated the patients with palpable breast mass who were ultrasound candidates for further examination of the nature of mass in 2014-2016. Axilla breast ultrasound was performed by two radiology professors. Based on the classification of the American Radiology Society and BIRADS system, various degrees of breast masses malignancy were identified, and then the patients were referred for biopsy. The pathologic results were compared with ultrasound reports, and consistency of the results and accuracy of ultrasound were examined with statistical tests. Data were analyzed by SPSS software (version 16). Results: Out of 37 biopsies of lesions with BIRADS-3 in ultrasound, two (5.4%) of the lesions resulted in malignant pathology. Out of 102 biopsies of lesions with BIRADS-4 in ultrasound, 65 (64%) resulted in benign pathology which indicates no consistency of pathology results with sonography in these cases. The sensitivity of the BIRADS-3 system for diagnosis of benign breast masses was 94% and its specificity was 64%. The sensitivity of the BIRADS-4 system for diagnosis of malignant breast cancers was 75% and its specificity was 79%. Conclusion: There was consistency between the results obtained from the classification by the BIRADS method and pathology; so regarding the relatively high accuracy of this method, radiologic-pathologic consistency can be used to determine how to follow the patients and choose the appropriate treatment method. 
546 |a FA 
690 |a birads 
690 |a breast cancer 
690 |a ultrasound 
690 |a Gynecology and obstetrics 
690 |a RG1-991 
655 7 |a article  |2 local 
786 0 |n Majallah-i Zanān, Māmā̓ī va Nāzā̓ī-i Īrān, Vol 22, Iss 6, Pp 1-6 (2019) 
787 0 |n https://ijogi.mums.ac.ir/article_13738_af95fefbaceca282624348bdb34b9b50.pdf 
787 0 |n https://doaj.org/toc/1680-2993 
787 0 |n https://doaj.org/toc/2008-2363 
856 4 1 |u https://doaj.org/article/c4026b5122544214922171d58ceef0fc  |z Connect to this object online.