The Accuracy of Four Impression-making Techniques in Angulated Implants Based on Vertical Gap

Statement of the Problem: Precision of the impression taken from implant positions significantly determines accurate fit of implant-supported prostheses. An imprecise impression may produce prosthesis misfit. Purpose: This study aimed to evaluate the accuracy of four impression-making techniques for...

Full description

Saved in:
Bibliographic Details
Main Authors: Abolfazl Saboury (Author), Hamid Neshandar Asli (Author), Zahra Dalili Kajan (Author)
Format: Book
Published: Shiraz University of Medical Sciences, 2017-12-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_c47d8732aa764a708feecd8048d1411d
042 |a dc 
100 1 0 |a Abolfazl Saboury   |e author 
700 1 0 |a Hamid Neshandar Asli   |e author 
700 1 0 |a Zahra Dalili Kajan   |e author 
245 0 0 |a The Accuracy of Four Impression-making Techniques in Angulated Implants Based on Vertical Gap 
260 |b Shiraz University of Medical Sciences,   |c 2017-12-01T00:00:00Z. 
500 |a 2345-6485 
500 |a 2345-6418 
520 |a Statement of the Problem: Precision of the impression taken from implant positions significantly determines accurate fit of implant-supported prostheses. An imprecise impression may produce prosthesis misfit. Purpose: This study aimed to evaluate the accuracy of four impression-making techniques for angulated implants by stereomicroscope through measuring the vertical marginal gaps between the cemented metal framework and the implant analog. Materials and Method: A definitive cast with two 15° mesially angulated implants served as the standard reference for making all the impressions and later for accuracy evaluation. Four groups of five samples were evaluated: (1) closed-tray snap-fit transfer, (2) open-tray nonsplinted impression coping, (3) metal splinted impression coping, and (4) fabricated acrylic resin transfer cap. A gold-palladium framework was fabricated over the angulated implant abutments, the fit of which was used as reference. The gaps between the metal framework and the implant analogs were measured in sample groups. Corresponding means for each technique and the definitive cast were compared by using ANOVA and post hoc tests. Results: The mean marginal gap was 38.16±0µm in definitive cast, 89±19.74µm in group 1, 78.66±20.63µm in group 2, 54.16±24.29µm in group 3, and 55.83±18.30µm in group 4. ANOVA revealed significant differences between the definitive cast and groups 1 and 2, but not with groups 3 and 4 (p< 0.05). Conclusion: Vertical gap measurements showed that metal splinted impression coping and fabricated acrylic resin transfer cap techniques produced quite more accurate impressions than closed-tray snap-fit transfer and open-tray nonsplinted impression coping techniques do. The fabricated acrylic resin transfer cap technique seems to be a reliable impression-making method. 
546 |a EN 
690 |a Dental Implants 
690 |a Impression techniques 
690 |a Dental 
690 |a Dental Abutments 
690 |a Dental Prosthesis 
690 |a Medicine 
690 |a R 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Journal of Dentistry, Vol 18, Iss 4, Pp 289-297 (2017) 
787 0 |n http://dentjods.sums.ac.ir/index.php/JDSUMS/article/view/1399/1089 
787 0 |n https://doaj.org/toc/2345-6485 
787 0 |n https://doaj.org/toc/2345-6418 
856 4 1 |u https://doaj.org/article/c47d8732aa764a708feecd8048d1411d  |z Connect to this object online.