Studying and Characterization of Coating of Zein-CaSiO3 Composite on Polyetheretherketone Implant Material

Material-coated implants are placed in the bone and play an essential role in bone regeneration and rapid healing around implants. Polymeric matrix reinforced with ceramic materials is a promising composite material for coating implants. This study aims to determine the effect of mixing various conc...

Full description

Saved in:
Bibliographic Details
Main Authors: Sama Abdulrazzaq (Author), Thekra Ismael Hamad (Author)
Format: Book
Published: Hindawi Limited, 2024-01-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_c532b333dfd74a8c8ac0c07a574babd4
042 |a dc 
100 1 0 |a Sama Abdulrazzaq  |e author 
700 1 0 |a Thekra Ismael Hamad  |e author 
245 0 0 |a Studying and Characterization of Coating of Zein-CaSiO3 Composite on Polyetheretherketone Implant Material 
260 |b Hindawi Limited,   |c 2024-01-01T00:00:00Z. 
500 |a 1687-8736 
500 |a 10.1155/2024/1592439 
520 |a Material-coated implants are placed in the bone and play an essential role in bone regeneration and rapid healing around implants. Polymeric matrix reinforced with ceramic materials is a promising composite material for coating implants. This study aims to determine the effect of mixing various concentrations of zein with CaSiO3 on polyetheretherketone (PEEK) as implant material. The coating was performed using the electrospray method. PEEK disks were used as a control group. The coated disks with different concentrations of zein-CaSiO3 (Group 1: 10% wt, 90% wt), (Group 2: 20% wt, 80% wt), and (Group 3%: 30% wt, 70% wt) were the experimental group. Each group was characterized by atomic force microscopy, field emission scanning electron microscope, Fourier-transform infrared spectroscopy, water contact angle, and adhesion strength. The lowest water contact angle was obtained for Group 1: 10% wt and 90% wt were (26.64° and 27.13°, respectively), and increasing amounts of zein in comparison to quantities of CaSiO3 resulted in increased adhesion strength of the composite material to the substrate. The current study suggested that the higher amount of zein compared to the amount of CaSiO3 mixture coating is achieved by electrospraying, a favorable candidate for coating implants compared to uncoated and coated disks with low concentrations of zein compared to concentrations of CaSiO3. 
546 |a EN 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n International Journal of Dentistry, Vol 2024 (2024) 
787 0 |n http://dx.doi.org/10.1155/2024/1592439 
787 0 |n https://doaj.org/toc/1687-8736 
856 4 1 |u https://doaj.org/article/c532b333dfd74a8c8ac0c07a574babd4  |z Connect to this object online.