Systematical approach in evaluation of LC method for determination of raloxifene hydrochloride and its impurities employing experimental design

Method validation presents a detailed investigation of analytical method and provision of the evidence that the method, when correctly applied, produces results that fit to the purpose. In order to achieve the method validation scope efficiently, experimental design presents a very useful tool. The...

Full description

Saved in:
Bibliographic Details
Main Authors: B. JanÄiÄ StojanoviÄ (Author), T. RakiÄ (Author), B. SlavkoviÄ (Author), N. KostiÄ (Author), A. VemiÄ (Author), A. MalenoviÄ (Author)
Format: Book
Published: Elsevier, 2013-02-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_c606857e68164804a07eca8a23f4be3c
042 |a dc 
100 1 0 |a B. JanÄiÄ StojanoviÄ  |e author 
700 1 0 |a T. RakiÄ  |e author 
700 1 0 |a B. SlavkoviÄ  |e author 
700 1 0 |a N. KostiÄ  |e author 
700 1 0 |a A. VemiÄ  |e author 
700 1 0 |a A. MalenoviÄ  |e author 
245 0 0 |a Systematical approach in evaluation of LC method for determination of raloxifene hydrochloride and its impurities employing experimental design 
260 |b Elsevier,   |c 2013-02-01T00:00:00Z. 
500 |a 2095-1779 
500 |a 10.1016/j.jpha.2012.09.007 
520 |a Method validation presents a detailed investigation of analytical method and provision of the evidence that the method, when correctly applied, produces results that fit to the purpose. In order to achieve the method validation scope efficiently, experimental design presents a very useful tool. The greatest benefits of such approach could be seen in robustness testing through the provision of very useful data about the control of the chromatographic system during the routine application. In this paper, robustness testing of the LC method proposed for the determination of raloxifene hydrochloride and its four impurities was done employing PlackettâBurman design. Applying this design, the effect of five real factors (acetonitrile content, sodium dodecyl sulfate content, column temperature, pH of the mobile phase and flow rate) on the corresponding resolution factors was investigated through twelve experiments. Furthermore, the insignificance intervals for significant factors were calculated and the parameters for system suitability tests were defined. Eventually, the other validation parameters were tested and the effectiveness of the proposed analytical method with a high degree of accuracy was confirmed. Keywords: Experimental design, Method validation, Raloxifene hydrochloride, Impurities, Liquid chromatography 
546 |a EN 
690 |a Therapeutics. Pharmacology 
690 |a RM1-950 
655 7 |a article  |2 local 
786 0 |n Journal of Pharmaceutical Analysis, Vol 3, Iss 1, Pp 45-52 (2013) 
787 0 |n http://www.sciencedirect.com/science/article/pii/S2095177912001141 
787 0 |n https://doaj.org/toc/2095-1779 
856 4 1 |u https://doaj.org/article/c606857e68164804a07eca8a23f4be3c  |z Connect to this object online.