ATP Bioluminometers Analysis on the Surfaces of Removable Orthodontic Aligners after the Use of Different Cleaning Methods

Purpose. The aim was to quantify the bacteria concentration on the surface of orthodontic clear aligners using three different cleaning methods. Furthermore the objective was to validate the efficacy of the bioluminometer in assessing the bacteria concentration. Materials and Methods. Twenty subject...

Full description

Saved in:
Bibliographic Details
Main Authors: Luca Levrini (Author), Alessandro Mangano (Author), Silvia Margherini (Author), Camilla Tenconi (Author), Davide Vigetti (Author), Raffaele Muollo (Author), Gian Marco Abbate (Author)
Format: Book
Published: Hindawi Limited, 2016-01-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_c64f8b0b171e4e089daa157064a49dfc
042 |a dc 
100 1 0 |a Luca Levrini  |e author 
700 1 0 |a Alessandro Mangano  |e author 
700 1 0 |a Silvia Margherini  |e author 
700 1 0 |a Camilla Tenconi  |e author 
700 1 0 |a Davide Vigetti  |e author 
700 1 0 |a Raffaele Muollo  |e author 
700 1 0 |a Gian Marco Abbate  |e author 
245 0 0 |a ATP Bioluminometers Analysis on the Surfaces of Removable Orthodontic Aligners after the Use of Different Cleaning Methods 
260 |b Hindawi Limited,   |c 2016-01-01T00:00:00Z. 
500 |a 1687-8728 
500 |a 1687-8736 
500 |a 10.1155/2016/5926941 
520 |a Purpose. The aim was to quantify the bacteria concentration on the surface of orthodontic clear aligners using three different cleaning methods. Furthermore the objective was to validate the efficacy of the bioluminometer in assessing the bacteria concentration. Materials and Methods. Twenty subjects (six males and fourteen females) undergoing orthodontic therapy with clear aligners (Invisalign® Align Technology, Santa Clara, California) were enrolled in this study. The observation time was of six weeks. The patients were instructed to use different cleaning methods (water, brushing with toothpaste, and brushing with toothpaste and use of sodium carbonate and sulphate tablet). At the end of each phase a microbiological analysis was performed using the bioluminometer. Results. The highest bacteria concentration was found on aligners cleaned using only water (583 relative light units); a value of 189 relative light units was found on aligners cleaned with brushing and toothpaste. The lowest bacteria concentration was recorded on aligners cleaned with brushing and toothpaste and the use of sodium carbonate and sulfate tablet. Conclusions. The mechanical removal of the bacterial biofilm proved to be effective with brushing and toothpaste. The best results in terms of bacteria concentration were achieved adding the use of sodium carbonate and sulfate tablet. 
546 |a EN 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n International Journal of Dentistry, Vol 2016 (2016) 
787 0 |n http://dx.doi.org/10.1155/2016/5926941 
787 0 |n https://doaj.org/toc/1687-8728 
787 0 |n https://doaj.org/toc/1687-8736 
856 4 1 |u https://doaj.org/article/c64f8b0b171e4e089daa157064a49dfc  |z Connect to this object online.