Deformation of nickel-titanium closed coil springs: an in vitro study
ABSTRACT Objective: The aim of this paper was to determine the amount of deformation in four commercial brands of nickel-titanium closed springs. Methods: A total of 130 springs were divided into 13 subgroups, according to their features and manufacturers (Morelli, Orthometric, Ormco and GAC) and ac...
Zapisane w:
Główni autorzy: | , , , , |
---|---|
Format: | Książka |
Wydane: |
Dental Press Editora.
|
Hasła przedmiotowe: | |
Dostęp online: | Connect to this object online. |
Etykiety: |
Dodaj etykietę
Nie ma etykietki, Dołącz pierwszą etykiete!
|
MARC
LEADER | 00000 am a22000003u 4500 | ||
---|---|---|---|
001 | doaj_c6885a19cac14a11bff199af2fde7d8b | ||
042 | |a dc | ||
100 | 1 | 0 | |a Camilla Ivini Viana Vieira |e author |
700 | 1 | 0 | |a José Maurício dos Santos Nunes Reis |e author |
700 | 1 | 0 | |a Luiz Geraldo Vaz |e author |
700 | 1 | 0 | |a Lídia Parsekian Martins |e author |
700 | 1 | 0 | |a Renato Parsekian Martins |e author |
245 | 0 | 0 | |a Deformation of nickel-titanium closed coil springs: an in vitro study |
260 | |b Dental Press Editora. | ||
500 | |a 2177-6709 | ||
500 | |a 10.1590/2177-6709.22.1.038-046.oar | ||
520 | |a ABSTRACT Objective: The aim of this paper was to determine the amount of deformation in four commercial brands of nickel-titanium closed springs. Methods: A total of 130 springs were divided into 13 subgroups, according to their features and manufacturers (Morelli, Orthometric, Ormco and GAC) and activated from 100% to 1000% of the effective length of the nickel-titanium portion present at the spring, at 37 °C. Deactivation data were plotted and deformation was found graphically. The values were compared by analysis of variance and Tukey's post-hoc test. Results: Springs manufactured by Morelli had the same amount of deformation when they were activated up to 700% of Y activation; springs by Orthometric had the same amount of deformation up to 600-700% of Y; springs by Ormco had the same amount of deformation up to 700-800% of Y; and finally, the majority of springs by GAC had similar deformation up to 800%-1000% of activation. All springs tested could be activated up to 700% without rupture. Conclusions: Most subgroups were similarly deformed up to 700% of activation, without rupture of springs. Subgroups 4B, 4C, 4D and 4E showed the same amount of deformation up to 1000% of activation without any rupture at all. | ||
546 | |a EN | ||
546 | |a PT | ||
690 | |a NiTi | ||
690 | |a Deformation | ||
690 | |a Biomechanics. | ||
690 | |a Dentistry | ||
690 | |a RK1-715 | ||
655 | 7 | |a article |2 local | |
786 | 0 | |n Dental Press Journal of Orthodontics, Vol 22, Iss 1, Pp 38-46 | |
787 | 0 | |n http://www.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512017000100038&lng=en&tlng=en | |
787 | 0 | |n https://doaj.org/toc/2177-6709 | |
856 | 4 | 1 | |u https://doaj.org/article/c6885a19cac14a11bff199af2fde7d8b |z Connect to this object online. |