Deformation of nickel-titanium closed coil springs: an in vitro study

ABSTRACT Objective: The aim of this paper was to determine the amount of deformation in four commercial brands of nickel-titanium closed springs. Methods: A total of 130 springs were divided into 13 subgroups, according to their features and manufacturers (Morelli, Orthometric, Ormco and GAC) and ac...

Szczegółowa specyfikacja

Zapisane w:
Opis bibliograficzny
Główni autorzy: Camilla Ivini Viana Vieira (Autor), José Maurício dos Santos Nunes Reis (Autor), Luiz Geraldo Vaz (Autor), Lídia Parsekian Martins (Autor), Renato Parsekian Martins (Autor)
Format: Książka
Wydane: Dental Press Editora.
Hasła przedmiotowe:
Dostęp online:Connect to this object online.
Etykiety: Dodaj etykietę
Nie ma etykietki, Dołącz pierwszą etykiete!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_c6885a19cac14a11bff199af2fde7d8b
042 |a dc 
100 1 0 |a Camilla Ivini Viana Vieira  |e author 
700 1 0 |a José Maurício dos Santos Nunes Reis  |e author 
700 1 0 |a Luiz Geraldo Vaz  |e author 
700 1 0 |a Lídia Parsekian Martins  |e author 
700 1 0 |a Renato Parsekian Martins  |e author 
245 0 0 |a Deformation of nickel-titanium closed coil springs: an in vitro study 
260 |b Dental Press Editora. 
500 |a 2177-6709 
500 |a 10.1590/2177-6709.22.1.038-046.oar 
520 |a ABSTRACT Objective: The aim of this paper was to determine the amount of deformation in four commercial brands of nickel-titanium closed springs. Methods: A total of 130 springs were divided into 13 subgroups, according to their features and manufacturers (Morelli, Orthometric, Ormco and GAC) and activated from 100% to 1000% of the effective length of the nickel-titanium portion present at the spring, at 37 °C. Deactivation data were plotted and deformation was found graphically. The values were compared by analysis of variance and Tukey's post-hoc test. Results: Springs manufactured by Morelli had the same amount of deformation when they were activated up to 700% of Y activation; springs by Orthometric had the same amount of deformation up to 600-700% of Y; springs by Ormco had the same amount of deformation up to 700-800% of Y; and finally, the majority of springs by GAC had similar deformation up to 800%-1000% of activation. All springs tested could be activated up to 700% without rupture. Conclusions: Most subgroups were similarly deformed up to 700% of activation, without rupture of springs. Subgroups 4B, 4C, 4D and 4E showed the same amount of deformation up to 1000% of activation without any rupture at all. 
546 |a EN 
546 |a PT 
690 |a NiTi 
690 |a Deformation 
690 |a Biomechanics. 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Dental Press Journal of Orthodontics, Vol 22, Iss 1, Pp 38-46 
787 0 |n http://www.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512017000100038&lng=en&tlng=en 
787 0 |n https://doaj.org/toc/2177-6709 
856 4 1 |u https://doaj.org/article/c6885a19cac14a11bff199af2fde7d8b  |z Connect to this object online.