DPP-IV Inhibitor-Associated Angioedema in Patient With Known History of ACE Inhibitor Angioedema

The patient is a 69-year-old male with a past medical history of intellectual disability, hypertension, type 2 diabetes mellitus, and angiotensin-converting enzyme (ACE) inhibitor-associated angioedema who presented to the emergency department with difficulty breathing. On physical examination, the...

Full description

Saved in:
Bibliographic Details
Main Authors: Chidinma Ejikeme MD (Author), Chinedu Nwachukwu MD (Author), John Luis Viechweg MD (Author), Ifunanya Ejikeme (Author), Micheal Brescia MD (Author)
Format: Book
Published: SAGE Publishing, 2021-07-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_c888da4e55f14e9a82ab3b52e5db14cf
042 |a dc 
100 1 0 |a Chidinma Ejikeme MD  |e author 
700 1 0 |a Chinedu Nwachukwu MD  |e author 
700 1 0 |a John Luis Viechweg MD  |e author 
700 1 0 |a Ifunanya Ejikeme  |e author 
700 1 0 |a Micheal Brescia MD  |e author 
245 0 0 |a DPP-IV Inhibitor-Associated Angioedema in Patient With Known History of ACE Inhibitor Angioedema 
260 |b SAGE Publishing,   |c 2021-07-01T00:00:00Z. 
500 |a 2324-7096 
500 |a 10.1177/23247096211033049 
520 |a The patient is a 69-year-old male with a past medical history of intellectual disability, hypertension, type 2 diabetes mellitus, and angiotensin-converting enzyme (ACE) inhibitor-associated angioedema who presented to the emergency department with difficulty breathing. On physical examination, the patient had significant facial edema. Nasal fiber-optic visualization revealed extensive airway edema involving the supraglottic region and the arytenoids. The patient was successfully intubated through the collective teamwork of ENT, anesthesia, and critical care teams. He was managed in the intensive care unit until recovery. Workup for markers for allergic causes of angioedema were within normal limits. Further investigation revealed that symptoms developed following the initiation of a dipeptidyl peptidase 4 (DPP-IV) inhibitor. The angiotensin-converting enzyme and DPP-IV play a significant role in the metabolism of bradykinin and substance P to their inactive metabolites. The complex interplay between the enzymes in the high-molecular-weight kininogen (HWMK) system may increase the risk of angioedema in patients with a known history of ACE inhibitor-associated angioedema when placed on a DPP-IV inhibitor. This case report highlights the pathophysiology involved. 
546 |a EN 
690 |a Medicine (General) 
690 |a R5-920 
690 |a Pathology 
690 |a RB1-214 
655 7 |a article  |2 local 
786 0 |n Journal of Investigative Medicine High Impact Case Reports, Vol 9 (2021) 
787 0 |n https://doi.org/10.1177/23247096211033049 
787 0 |n https://doaj.org/toc/2324-7096 
856 4 1 |u https://doaj.org/article/c888da4e55f14e9a82ab3b52e5db14cf  |z Connect to this object online.