Impact of recycling on the mechanical properties of nickel-titanium alloy wires and the efficacy of their reuse after cold sterilization
OBJECTIVE: This study aimed to assess the feasibility of reusing nickel-titanium (NiTi) alloy wires after 6 weeks of intraoral use by evaluating the changes in the load-deflection properties and surface characterization of these alloy wires after cold sterilization by immersion in 2% of acidic gluta...
Saved in:
Main Authors: | Ankit Yadav (Author), Poonam K Jayaprakash (Author), Rajeshwar Singh (Author), Meeta Dawer (Author), Palash Modi (Author), Bhumika Sehdev (Author), Kiran K Ganji (Author) |
---|---|
Format: | Book |
Published: |
Wolters Kluwer Medknow Publications,
2020-01-01T00:00:00Z.
|
Subjects: | |
Online Access: | Connect to this object online. |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Similar Items
-
Effect of ion-implantation on surface characteristics of nickel titanium and titanium molybdenum alloy arch wires
by: Manu Krishnan, et al.
Published: (2013) -
EcoHealth Center: reduce, reuse, recycle!
by: Sofia Monteiro, et al.
Published: (2023) -
The Road to Sustainability in Dentistry - Is the Reuse of Sterilization Pouches Viable?
by: Catarina Amaral, et al.
Published: (2023) -
The effect of different clinical recycling methods on load deflection properties of super-elastic and thermal nickel-titanium orthodontic arch wires: A comparative assessment
by: Priti Shukla, et al.
Published: (2024) -
Nickel-titanium alloys: a systematic review
by: Marcelo do Amaral Ferreira, et al.
Published: (2012)