Evaluation of the accuracy of cone beam computed tomography (CBCT) in the detection of peri-implant fenestration

Abstract Background Accurate assessment of the bone supporting the implant is crucial. Early detection of bone defects around the implant can prevent the loss of bone support that ultimately leads to the loss of the implant. Therefore, the purpose of this study is to check the accuracy of CBCT in de...

Full description

Saved in:
Bibliographic Details
Main Authors: Atefeh Gholampour (Author), Melika Mollaei (Author), Hodis Ehsani (Author), Fatemeh Ghobadi (Author), Abolfazl Hosseinnataj (Author), Mehdi Yazdani (Author)
Format: Book
Published: BMC, 2024-08-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_c8f1bc8edcea4280a2c014d7cabd7ab4
042 |a dc 
100 1 0 |a Atefeh Gholampour  |e author 
700 1 0 |a Melika Mollaei  |e author 
700 1 0 |a Hodis Ehsani  |e author 
700 1 0 |a Fatemeh Ghobadi  |e author 
700 1 0 |a Abolfazl Hosseinnataj  |e author 
700 1 0 |a Mehdi Yazdani  |e author 
245 0 0 |a Evaluation of the accuracy of cone beam computed tomography (CBCT) in the detection of peri-implant fenestration 
260 |b BMC,   |c 2024-08-01T00:00:00Z. 
500 |a 10.1186/s12903-024-04674-z 
500 |a 1472-6831 
520 |a Abstract Background Accurate assessment of the bone supporting the implant is crucial. Early detection of bone defects around the implant can prevent the loss of bone support that ultimately leads to the loss of the implant. Therefore, the purpose of this study is to check the accuracy of CBCT in detecting peri-implant fenestrations around the implant. Materials & methods In this laboratory study, healthy beef ribs were used. The ribs were divided into three groups of 12 (control group, 1-2 mm fenestration group, and 2-3 mm fenestration group). The blocks were cut to a length of 20 mm and 36 osteotomies with dimensions of 4 × 12 mm were made by the periodontist in order to place the implant in these bone blocks. Then the titanium implant was placed in the holes and the initial scan was performed with CBCT. In the second group, fenestration-like lesions were created on the same buccal side at a distance of 10 mm from the crest with a diameter of 1-2 mm and in the third group with a diameter of 2-3 mm, and the CBCT scan was performed again with the same parameters. Two radiologists evaluated the images twice for the presence and absence of fenestration. Results There was no statistically significant difference between direct measurements and CBCT in the fenestration group of 1-2 mm (p < 0.05), but there was a significant difference between direct measurements and CBCT in the fenestration group of 2-3 mm and underestimation was observed in CBCT measurements. Conclusion The findings of this study showed that CBCT radiography has a higher accuracy in measuring the fenestration around the implant with a smaller diameter and has an acceptable diagnostic value in detecting bone loss around the implant. 
546 |a EN 
690 |a Cone beam computed tomography 
690 |a Dental implant 
690 |a Peri-implant fenestration 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n BMC Oral Health, Vol 24, Iss 1, Pp 1-7 (2024) 
787 0 |n https://doi.org/10.1186/s12903-024-04674-z 
787 0 |n https://doaj.org/toc/1472-6831 
856 4 1 |u https://doaj.org/article/c8f1bc8edcea4280a2c014d7cabd7ab4  |z Connect to this object online.