Concordance of the vestibular bone thickness at the level of point a between teleradiography and cone beam computed tomography.

Objective: The aim of this study was to determine the concordance of the vestibular bone thickness measured at the level of point A between Teleradiography and Cone Beam Computed Tomography (CBCT). Materials and Methods: This study consisted of a cross-sectional analytical design of concordance that...

Full description

Saved in:
Bibliographic Details
Main Authors: Carolina Vergara (Author), Sebastián Espinoza (Author), Paulina González (Author), Camila Martens (Author), Patricio Rojas (Author), Pedro Córdova (Author)
Format: Book
Published: Universidad de Concepción., 2023-01-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_cae24968bbcb4c7d8d6f7a763f80e36f
042 |a dc 
100 1 0 |a Carolina Vergara  |e author 
700 1 0 |a Sebastián Espinoza  |e author 
700 1 0 |a Paulina González  |e author 
700 1 0 |a Camila Martens  |e author 
700 1 0 |a Patricio Rojas  |e author 
700 1 0 |a Pedro Córdova  |e author 
245 0 0 |a Concordance of the vestibular bone thickness at the level of point a between teleradiography and cone beam computed tomography. 
260 |b Universidad de Concepción.,   |c 2023-01-01T00:00:00Z. 
500 |a https://doi.org/10.17126/joralres.2023.006 
500 |a 0719-2460 
500 |a 0719-2479 
520 |a Objective: The aim of this study was to determine the concordance of the vestibular bone thickness measured at the level of point A between Teleradiography and Cone Beam Computed Tomography (CBCT). Materials and Methods: This study consisted of a cross-sectional analytical design of concordance that evaluated the teleradiographies and CBCTs of 32 patients. The measurements were performed by three evaluators, specialists in orthodontics. Two of them measured the CBCTs and one evaluated the teleradiographs. The concordance of both tests was determined using the Concordance Correlation Coefficient. Results: When evaluating the value of the vestibular bone thickness at the level of point A between the CBCT and the teleradiography, it was observed that the mean value of the absolute difference between the two was 0.95±0.74, 95%CI [0.68-1.22], being statistically significant (p=0.0027). When the concordance between both tests was analyzed, it was observed that it was poor (CCC=0.204 95%CI [0.014-0.394]), although statistically significant (p<0.00001). Conclusions: It was possible to conclude that there is no concordance in the measurement of the vestibular bone thickness at the level of Point A between the Teleradiography and the CBCT. 
546 |a EN 
690 |a cone-beam computed tomography 
690 |a orthodontics 
690 |a cephalometry 
690 |a incisor 
690 |a patients 
690 |a cross-sectional studies 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Journal of Oral Research, Vol 12, Iss 1, Pp 63-74 (2023) 
787 0 |n https://joralres.com/index.php/JOralRes/article/view/joralres.2023.006/1118 
787 0 |n https://doaj.org/toc/0719-2460 
787 0 |n https://doaj.org/toc/0719-2479 
856 4 1 |u https://doaj.org/article/cae24968bbcb4c7d8d6f7a763f80e36f  |z Connect to this object online.