Evaluation of Strain Distribution in Bone around Implant in Treatment Design of Overdentures Using Computer and Modeling of Finite Elements

Introduction: Introduction: Few studies have investigated the distribution of stress around implants. In this study the distribution of stress in bones around implants was investigated in five overdenture (OD) treatment designs including OD-1, OD-2, OD-3, OD-4 and OD-5. Materials and methods: The Ca...

Full description

Saved in:
Bibliographic Details
Main Authors: Masoumeh Khoshhal (Author), Fariborz Vafaee (Author), Sahar Raisi (Author)
Format: Book
Published: Mashhad University of Medical Sciences, 2016-03-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_cc42b851a64848bdb8a72c44f132a0ea
042 |a dc 
100 1 0 |a Masoumeh Khoshhal  |e author 
700 1 0 |a Fariborz Vafaee  |e author 
700 1 0 |a Sahar Raisi  |e author 
245 0 0 |a Evaluation of Strain Distribution in Bone around Implant in Treatment Design of Overdentures Using Computer and Modeling of Finite Elements 
260 |b Mashhad University of Medical Sciences,   |c 2016-03-01T00:00:00Z. 
500 |a 2322-4150 
500 |a 2252-0317 
500 |a 10.22038/jdmt.2015.6245 
520 |a Introduction: Introduction: Few studies have investigated the distribution of stress around implants. In this study the distribution of stress in bones around implants was investigated in five overdenture (OD) treatment designs including OD-1, OD-2, OD-3, OD-4 and OD-5. Materials and methods: The Catia modeling software was used in order to simulate the tooth/implant model and bone. First, the borders of cancellous and cortical bone in each section of the CT images were attained by Photoshop software. Then, modeling softwares SolidWorks and NUMBER were applied to make the final three-dimensional model of jaw. Finally, the amount of stress on the surface of bone/implant was studied by means of stress analysis software (Ansys v11.0). Results: Protrusive movements of implants B and D in OD-1 showed the highest amount of strain, 2435 εµ. Also, high amounts of strain, 1668 and 1557 εµwere observed in OD-1 and OD-2 designs in lateral movements respectively. Conclusion: The bottom line is that no forces to the extent of destruction based on the Ferost model were found for these designs. The highest amount of strain occurred in OD-1 design, which is held in mild overload window. Moreover, the amounts of strain in the rest of designs investigated were in adaptive window. 
546 |a EN 
690 |a Dental implant 
690 |a stress distribution 
690 |a overdenture 
690 |a Frost model 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Journal of Dental Materials and Techniques, Vol 5, Iss 1, Pp 11-16 (2016) 
787 0 |n http://jdmt.mums.ac.ir/article_6245_954772526022d83f3aa1bfaa94c34a0d.pdf 
787 0 |n https://doaj.org/toc/2322-4150 
787 0 |n https://doaj.org/toc/2252-0317 
856 4 1 |u https://doaj.org/article/cc42b851a64848bdb8a72c44f132a0ea  |z Connect to this object online.