Comparison of three device generations of the StepWatch Activity Monitor: analysis of model version agreement in pediatric and adult independent ambulators

PurposeDevices such as the StepWatch Activity Monitor (SAM) have been available for 20 years and have been shown to accurately measure ambulatory activity. This study aimed to evaluate the agreement among the three generations of the StepWatch Activity Monitor (SW3, SW4, and SW5) with respect to str...

Full description

Saved in:
Bibliographic Details
Main Authors: Wilshaw R. Stevens (Author), Cody Barrett (Author), Kelly A. Jeans (Author)
Format: Book
Published: Frontiers Media S.A., 2024-07-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_cd1c6a18e7d045d0a5db209d2a2a8f8c
042 |a dc 
100 1 0 |a Wilshaw R. Stevens  |e author 
700 1 0 |a Cody Barrett  |e author 
700 1 0 |a Kelly A. Jeans  |e author 
245 0 0 |a Comparison of three device generations of the StepWatch Activity Monitor: analysis of model version agreement in pediatric and adult independent ambulators 
260 |b Frontiers Media S.A.,   |c 2024-07-01T00:00:00Z. 
500 |a 2624-9367 
500 |a 10.3389/fspor.2024.1418018 
520 |a PurposeDevices such as the StepWatch Activity Monitor (SAM) have been available for 20 years and have been shown to accurately measure ambulatory activity. This study aimed to evaluate the agreement among the three generations of the StepWatch Activity Monitor (SW3, SW4, and SW5) with respect to stride count.MethodsA total of 36 participants (age range, 6-55 years) participated in this institutional review board-approved study. The participants concurrently wore three different SAM model devices on the same leg and performed a 6-min walk test (6MWT). A research staff member of the laboratory manually counted the number of strides for the first 2 min of the test (2MWT). Agreement among the device models was evaluated by calculating ANOVAs and interclass correlation coefficients (ICCs) and creating Bland-Altman plots.ResultsThere was no significant difference among the model versions during the 6MWT and 2MWT (p > 0.05). The ICC for the total stride count was 0.993 (95% CI = 0.988-0.996) during the 2MWT and 0.992 (95% CI = 0.986-0.996) during the 6MWT. There was a near-perfect agreement (ICC ≥ 0.990) of each model version to the manually counted strides during the 2MWT. The systematic bias of all three SAM model versions was <1 step.ConclusionsThe results from the present study demonstrate that the stride counts among all three devices are comparable and relative to the manual stride count. All three SAM model versions had an ICC of >0.90. Researchers can safely incorporate historical data from previous SAM model versions with newer data collected with the latest SAM model version. 
546 |a EN 
690 |a accelerometer 
690 |a ambulatory activity 
690 |a adults 
690 |a pediatrics 
690 |a reliability 
690 |a agreement 
690 |a Sports 
690 |a GV557-1198.995 
655 7 |a article  |2 local 
786 0 |n Frontiers in Sports and Active Living, Vol 6 (2024) 
787 0 |n https://www.frontiersin.org/articles/10.3389/fspor.2024.1418018/full 
787 0 |n https://doaj.org/toc/2624-9367 
856 4 1 |u https://doaj.org/article/cd1c6a18e7d045d0a5db209d2a2a8f8c  |z Connect to this object online.