Iron and Zinc Determination in Dietary Supplements by Flame Atomic Absorption Spectrophotometry

Abstract Recent studies have demonstrated that 30% of the world's population suffers of anemia, half of the cases are related to iron deficiency, and the most common treatment is the use of iron supplementation. In this framework, the iron and zinc determination from different dietary supplemen...

Full description

Saved in:
Bibliographic Details
Main Author: Sabriye Aydinoglu (Author)
Format: Book
Published: Universidade de São Paulo, 2023-01-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_d064f1e89fbc4fc7a29467f952b6c4a1
042 |a dc 
100 1 0 |a Sabriye Aydinoglu  |e author 
245 0 0 |a Iron and Zinc Determination in Dietary Supplements by Flame Atomic Absorption Spectrophotometry 
260 |b Universidade de São Paulo,   |c 2023-01-01T00:00:00Z. 
500 |a 2175-9790 
500 |a 10.1590/s2175-97902022e21094 
520 |a Abstract Recent studies have demonstrated that 30% of the world's population suffers of anemia, half of the cases are related to iron deficiency, and the most common treatment is the use of iron supplementation. In this framework, the iron and zinc determination from different dietary supplements was performed by flame atomic absorption spectrophotometry. Concerning the dissolution of supplements, direct acid dissolution, wet digestion, and microwave digestion (MW) techniques were used for sample preparation. The iron and zinc recovery results demonstrated that the MW technique was the most appropriate for all of the supplements with the highest metal recovery yields. Moreover, the method validation parameters referred to a linear range for iron of 0.1-4 mg L-1 with a regression coefficient (R2) of 0.9998 ± 0.002, while for zinc it was 0.01-1 mg L-1 (R2 = 0.9997 ± 0.003). The limit of detection and quantification values were calculated as 0.03 and 0.09 mg L-1 for iron and 0.01 and 0.02 mg L-1 for zinc, respectively. The accuracy of the method was evaluated from the % recovery yield for iron and zinc, which, respectively, resulted in an oscillate of 99.2% to 102%, and 99.4% to 100.4% for the dietary investigated supplements. The precision of the method was determined by intra-day and inter-day precision with a relative standard deviation that was <2.0%. 
546 |a EN 
690 |a Iron 
690 |a Zinc 
690 |a Dietary Supplement 
690 |a Validation 
690 |a Pharmacy and materia medica 
690 |a RS1-441 
655 7 |a article  |2 local 
786 0 |n Brazilian Journal of Pharmaceutical Sciences, Vol 58 (2023) 
787 0 |n http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1984-82502022000100863&tlng=en 
787 0 |n https://doaj.org/toc/2175-9790 
856 4 1 |u https://doaj.org/article/d064f1e89fbc4fc7a29467f952b6c4a1  |z Connect to this object online.