Use of caliper-based external measurement of body surface in assessing the severity of pectus excavatum

IntroductionObjective assessment of the severity of pectus excavatum (PE) mainly depends on internal imaging examination, which poses radiation exposure risks and high financial costs. Our study explores the feasibility of caliper-based external measurements of the body surface to assess PE severity...

সম্পূর্ণ বিবরণ

সংরক্ষণ করুন:
গ্রন্থ-পঞ্জীর বিবরন
প্রধান লেখক: Tian Chen (Author), Chenghao Chen (Author), Qi Zeng (Author), Yan Zhang (Author), Jinghua Jiao (Author), Xu Zhang (Author), Na Zhang (Author), Jie Yu (Author)
বিন্যাস: গ্রন্থ
প্রকাশিত: Frontiers Media S.A., 2022-09-01T00:00:00Z.
বিষয়গুলি:
অনলাইন ব্যবহার করুন:Connect to this object online.
ট্যাগগুলো: ট্যাগ যুক্ত করুন
কোনো ট্যাগ নেই, প্রথমজন হিসাবে ট্যাগ করুন!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_d0ecc690fa944ca9aa314f9f1a3e38ac
042 |a dc 
100 1 0 |a Tian Chen  |e author 
700 1 0 |a Chenghao Chen  |e author 
700 1 0 |a Qi Zeng  |e author 
700 1 0 |a Yan Zhang  |e author 
700 1 0 |a Jinghua Jiao  |e author 
700 1 0 |a Xu Zhang  |e author 
700 1 0 |a Na Zhang  |e author 
700 1 0 |a Jie Yu  |e author 
245 0 0 |a Use of caliper-based external measurement of body surface in assessing the severity of pectus excavatum 
260 |b Frontiers Media S.A.,   |c 2022-09-01T00:00:00Z. 
500 |a 2296-2360 
500 |a 10.3389/fped.2022.1015026 
520 |a IntroductionObjective assessment of the severity of pectus excavatum (PE) mainly depends on internal imaging examination, which poses radiation exposure risks and high financial costs. Our study explores the feasibility of caliper-based external measurements of the body surface to assess PE severity.Materials and methodsPatients with PE aged 4-18 years who underwent both internal imaging examinations and external measurements were chosen for the study. Overall, 176 patients underwent surgery and 21 underwent regular observation. The Haller index (HI) and correction index (CI) were used to derive the external measurement indices, HI-caliper and CI-caliper. Receiver-operator characteristic analysis provided the optimal cut-off values and compared the diagnostic values of HI-caliper and CI-caliper. Spearman's correlation coefficient and Cohen's kappa coefficient were used to analyze the correlation and consistency between HI-caliper or CI-caliper and HI-CT or CI-CT, respectively. Also, a paired samples t-test was used to compare the differences of HI-caliper or CI-caliper before and after surgery.ResultsHI-caliper and CI-caliper measurements had strong correlations with HI-CT and CI-CT results (rs = 0.70, p < 0.001; rs = 0.69, p < 0.001), respectively. The optimal cut-off values of HI-caliper and CI-caliper were 1.83 (sensitivity = 0.841, specificity = 0.905) and 12% (sensitivity = 0.881, specificity = 0.857), exhibiting comparable diagnostic values with HI-CT and CI-CT. HI-caliper > 1.83 or CI-caliper > 12% had medium intensity consistency with HI-CT ≥ 3.25 or CI-CT ≥ 28% (k = 0.545, 95% confidence interval: 0.374-0.716, p < 0.001). The HI-caliper and CI-caliper values were significantly different before and after surgery.ConclusionCaliper-based external measurement is a feasible method to screen patients who require surgical intervention and for monitoring the progression of PE severity. 
546 |a EN 
690 |a pectus excavatum 
690 |a external measurement 
690 |a severity index 
690 |a caliper 
690 |a screening 
690 |a follow-up 
690 |a Pediatrics 
690 |a RJ1-570 
655 7 |a article  |2 local 
786 0 |n Frontiers in Pediatrics, Vol 10 (2022) 
787 0 |n https://www.frontiersin.org/articles/10.3389/fped.2022.1015026/full 
787 0 |n https://doaj.org/toc/2296-2360 
856 4 1 |u https://doaj.org/article/d0ecc690fa944ca9aa314f9f1a3e38ac  |z Connect to this object online.