Evaluating dental implant stability using three devices Osstell®, Periotest®, and AnyCheck®: a clinical study
Introduction: Implant stability is usually measured with resonance frequency analysis (RFA) and damping capacity assessment (DCA). This study aimed to measure primary and secondary stabilities using 3 devices that are based on these methods, namely; RFA (Osstell®) and DCA (Periotest® and AnyCheck®)...
Saved in:
Main Authors: | , |
---|---|
Format: | Book |
Published: |
EDP Sciences,
2024-01-01T00:00:00Z.
|
Subjects: | |
Online Access: | Connect to this object online. |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
MARC
LEADER | 00000 am a22000003u 4500 | ||
---|---|---|---|
001 | doaj_d1d2a64982d34a39b17d1c41c7df9794 | ||
042 | |a dc | ||
100 | 1 | 0 | |a Dhahi Alamin Y. |e author |
700 | 1 | 0 | |a Bede Salwan Y. |e author |
245 | 0 | 0 | |a Evaluating dental implant stability using three devices Osstell®, Periotest®, and AnyCheck®: a clinical study |
260 | |b EDP Sciences, |c 2024-01-01T00:00:00Z. | ||
500 | |a 2608-1326 | ||
500 | |a 10.1051/mbcb/2024023 | ||
520 | |a Introduction: Implant stability is usually measured with resonance frequency analysis (RFA) and damping capacity assessment (DCA). This study aimed to measure primary and secondary stabilities using 3 devices that are based on these methods, namely; RFA (Osstell®) and DCA (Periotest® and AnyCheck®) to assess the correlations of the measurements obtained by these devices and the correlations between implant stability and insertion torque. Material and Methods: This observational prospective study included 35 dental implants. The implant stability was measured using the 3 devices. Mann-Whitney U test and unpaired t-test assessed the relationship between implant stability and insertion torque, while the Spearman and Pearson correlations measured the correlation between readings collected via the 3 devices for the primary and secondary stabilities. Results: For the primary stability, there was a strong positive correlation between Osstell® and AnyCheck® and moderate negative correlations between Periotest® and both Osstell® and AnyCheck®. While for the secondary stability, strong correlations with similar patterns were observed among the 3 devices. The stability measurements showed significant relationships with the insertion torque. Conclusions: The 3 devices are reliable in measuring implant stability; also, high insertion torque can lead to improved implant stabilities (primary and secondary). | ||
546 | |a EN | ||
690 | |a implant stability | ||
690 | |a resonance frequency analysis | ||
690 | |a damping capacity assessment | ||
690 | |a Dentistry | ||
690 | |a RK1-715 | ||
690 | |a Surgery | ||
690 | |a RD1-811 | ||
655 | 7 | |a article |2 local | |
786 | 0 | |n Journal of Oral Medicine and Oral Surgery, Vol 30, Iss 3, p 20 (2024) | |
787 | 0 | |n https://www.jomos.org/articles/mbcb/full_html/2024/03/mbcb230180/mbcb230180.html | |
787 | 0 | |n https://doaj.org/toc/2608-1326 | |
856 | 4 | 1 | |u https://doaj.org/article/d1d2a64982d34a39b17d1c41c7df9794 |z Connect to this object online. |