Color Stability Assessment of Three Different Resin Composites After Polymerization with Two Different Light-Curing Units

Purpose: Despite improvements in resin composite structures, color stability remains a challenge, and esthetic problems are the most common factors in renewing restorations. This study aimed to evaluate the effects of two light-curing units on the color stability of three different resin composite m...

Full description

Saved in:
Bibliographic Details
Main Authors: Adil Nalcaci (Author), Ruhsan Müdüroğlu Adıgüzel (Author)
Format: Book
Published: Ankara University, 2023-08-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_d6bd5f3da18142f19dc8a1de3c4c18c0
042 |a dc 
100 1 0 |a Adil Nalcaci  |e author 
700 1 0 |a Ruhsan Müdüroğlu Adıgüzel  |e author 
245 0 0 |a Color Stability Assessment of Three Different Resin Composites After Polymerization with Two Different Light-Curing Units 
260 |b Ankara University,   |c 2023-08-01T00:00:00Z. 
500 |a 2757-6744 
500 |a 10.52037/eads.2023.0019 
520 |a Purpose: Despite improvements in resin composite structures, color stability remains a challenge, and esthetic problems are the most common factors in renewing restorations. This study aimed to evaluate the effects of two light-curing units on the color stability of three different resin composite materials during a six-month period. Materials Methods: Three different resin composites (Filtek Z550, Filtek Ultimate Flowable, Filtek Bulk Fill Restorative) with an A2 color shade were prepared for each combination of resin composite-curing unit (5x2mm) for a total of 30 specimens. Specimens were cured with either QTH Hilux Ultraplus (700mW/cm2) for 40 seconds or Radii Plus LED Curing Light (1400mW/cm2) for 20 seconds. For standardization of the amount of transmitted energy to the composite, all specimens received 28J/cm2. Color parameters were measured with a colorimeter (Minolta CR-321, Konica Minolta Sensing Pte Ltd, Singapore) after polymerization and at 24 hours, first week, first month, third month, and sixth month. Color changes(∆E) were calculated for the different storage periods. One-factor repeated three-way analysis of variance (ANOVA) was used to examine the changes in ΔE measurements over time for different fillers and devices. Results: Significant differences between composites and periods were observed in the color stability with polymerization either QTH or LED. Independently of the composites, there was no significant difference at the end of six months between QTH and LED units with a fixed energy density. The Filtek Z550 material showed the smallest and the Filtek Ultimate Flowable material showed the highest ∆E values at the end of the six months among the materials used. Conclusion: Clinically acceptable color changes were observed for all the materials at the end of six months. 
546 |a EN 
690 |a resin composites 
690 |a color stability 
690 |a quartz tungsten halogen 
690 |a light emitting diode 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n European Annals of Dental Sciences, Vol 50, Iss 2, Pp 70-75 (2023) 
787 0 |n https://dergipark.org.tr/en/download/article-file/2940643 
787 0 |n https://doaj.org/toc/2757-6744 
856 4 1 |u https://doaj.org/article/d6bd5f3da18142f19dc8a1de3c4c18c0  |z Connect to this object online.